Download Print this page

Configuring The Mps; Setup And Operation - Extron electronics MPS 601 Setup Manual

Hide thumbs Also See for MPS 601:

Advertisement

ATTENTION:
The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA
70, article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently fixed to
building structure or similar structure.
Cette installation doit toujours être en accord avec les mesures qui s'applique au National Electrical Code ANSI/
NFPA 70, article 725, et au Canadian Electrical Code, partie 1, section 16. La source d'alimentation ne devra pas être
fixée de façon permanente à une structure de bâtiment ou à une structure similaire.
This product is intended for use with a UL Listed power source marked Class 2 or LPS and rated 12VDC, minimum
0.5 A.
Ce produit est destiné à une utilisation avec une source d'alimentation certifiée UL de classe 2 ou LPS et calibrée à 12
Vcc, 0,5 A minimum.

Configuring the MPS 601

The MPS 601 can be configured using a connected PC and the Extron Product Configuration Software or using SIS commands.
To configure the MPS 601 using the Product Configuration Software, install the software (available on the Extron website, www.
extron.com) on a PC connected to the MPS 601 by the rear panel remote (RS-232) port (see figure 1, h), or front panel USB
Config port (see figure 6, b). After the installation, start the program. See the MPS 601 User Guide and the Product Configuration
Software Help File for additional information.
To configure the MPS 601 using SIS commands, see the MPS 601 User Guide.
1
AUTO
SWITCH
CONFIG
Figure 2.
MPS 601 Front Panel

Setup and Operation

Power on all connected devices, then apply power to the MPS 601. The Auto Switch LED lights when auto-input switching is
A
active.
One mini type-B female USB Config port connects to a host computer for configuring the switcher and upgrading firmware.
B
Input switching. The input group has six buttons with associated green LEDs. Press an input button to switch the input to the
C
HDMI output. The associated LED lights. Only one of the six inputs can be selected at a time.
Input signal LEDs. Six green LEDs indicate:
D
The LEDs for RGBHV inputs 1 and 2 light when horizontal sync is detected on the input.
The LEDs for HDMI inputs 3 to 6 light when TMDS clock activity is detected on the input.
NOTE:
If a connected HDMI source is HDCP encrypted, the associated input signal LED does not light until HDCP is
authenticated.
Output signal LED. This LED lights when the HDMI output is connected to a display or sink device.
E
F
HDCP input signal LEDs (inputs 3, 4, 5, and 6). These LEDs light for the associated HDMI input when the connected source is
HDCP encrypted.
HDCP output LED. This LED lights when the currently selected input source requires HDCP and the connected output device
G
(sink) is authenticated.
The MPS 601 can be connected to as many as six input devices. Any of the six inputs (2 RGBHV, 4 HDMI) can be routed to the
HDMI output.
INPUTS
2
3
4
5
INPUTS
OUTPUT
SIGNAL
6
1
2
3
4
5
6