  • Page 1 CE1122SS / CE1122WH Contact Caple on 0117 938 7420 or for spare parts www.caple.co.uk...
  • Page 2: Table Of Contents

    CONTENTS WARNINGS ENVIRONMENTAL PROTECTION INSTALLATION FREESTANDING INSTALLATION BUILT-IN INSTALLATION REMOTE CONTROL TIMING MAINTENANCE Please keep this instruction manual for future reference Instruction manual CE1122...
  • Page 3: Warnings

    WARNINGS - This appliance is not intended to be used by young children or infirm persons without supervision. Young children should be supervised to ensure they do not play with the appliance. - The air extracted cannot be conveyed through or into a duct used to let out fumes from appliances fed by energy other than electric power (eg.
  • Page 4 - When performing the electrical connections on the appliance, please make sure that the current tap is provided with earth connection and that voltage values correspond to those indicated on the rating label placed inside the appliance itself. - Before carrying out any cleaning or maintaining operations, the appliance needs to be removed from the electric grid.
  • Page 5 - This appliance complies with all relevant local and national safety requirements. Inappropriate use can, however, lead to personal injury and damage to property. - The cooker hood is not intended for outdoor use. - It must only be used as a domestic appliance to extract vapours and remove odours from cooking.
  • Page 6 - Do not connect the appliance to the mains electricity supply by a multi-socket unit or an extension lead. These are a fire hazard and do not guarantee the required safety of the appliance. - The cooker hood can get very hot during cooking due to heat rising from the hob.
  • Page 7: Environmental Protection

    Radio Equipment Directive (RED) 2014/53/EU This Declaration is issued under the sole responsibility of the manufacturer. Hereby, Caple declares that the radio equipment included in the product is in compliance with the RED directive 2014/53/EU. The full text of the EU Declaration of Conformity is available on our website www.caple.co.uk.
  • Page 8: Installation

    - Use a 150 mm constant diameter pipe for the whole length. - Use ducting approved by the local standards inforce. NOTE: For more information on venting, please see our ‘Extraction & Ventilation guide’ available on our website www.caple.co.uk. Please keep this instruction manual for future reference Instruction manual CE1122...
  • Page 9: Freestanding Installation

    FREESTANDING INSTALLATION Recirculating version The product is ready for this version. Attention: Let the power cord pass through the hood hole, as shown in fig. 2. Mark the holes to fix the product to the false ceiling. Having marked the holes, make them by using a drill bit (diameter 8mm), and place in the holes the metric fixing plugs provided.
  • Page 10 Ducted version Turn the motor to evacuate the air from the upper side of the hood. Open the glass panels, and remove grease filters and carbon filters. Remove the four screws shown in picture 4. Remove the lower stainless steel as shown in picture 5.
  • Page 11: Built-In Installation

    BUILT-IN INSTALLATION In case of built-in version remove the stainless steel cover (fig.11) Ducted version Mark the holes to fix the product into the false ceiling (Fig.3). Make the the holes marked, by a drill bit diameter 8mm, and place the metric plugs provided in the holes.
  • Page 12 Make the electicial connection into the metal box. The power supply metal box is positioned close to the electrical components and you can see them after removing the grease filters. Please connect the cables as you can see in picture 18. Ducting is not supplied with the product, this is to be supplied by the installer depending on the installation requirements.
  • Page 13 Please keep this instruction manual for future reference Instruction manual CE1122...
  • Page 14 Please keep this instruction manual for future reference Instruction manual CE1122...
  • Page 15 Please keep this instruction manual for future reference Instruction manual CE1122...
  • Page 16 Please keep this instruction manual for future reference Instruction manual CE1122...
  • Page 17: Remote Control

    REMOTE CONTROL At first ignition, keep pressed the lighting button for 5 seconds. Remote control used for the operation of cooker hoods: Technical Data Alkaline battery powered : 12 V mod. 23 A Operating frequency : 433.92 Mhz Combinations : 32.768 Max.
  • Page 18 Initial Operating Condition The manufacturer supplies the remote control unit ready to be used with codes preset in the Factory OPERATION MODE Standard configuration: Standard configuration requires all “cooker hoods radio control system” to be provided with the same transmission code. In the event two cooker hoods radio control system are installed in the same room or nearby, each system may affect the operation of the another.
  • Page 19 Reset of the Factory configuration: To restore the Factory configuration, follow the procedure described below: press simultaneously buttons for 2 seconds. When Leds light on, press buttons (within 5 seconds). Leds flashing 6 times indicate the procedure is completed. WARNING: This operation deletes permanently the preset codes.
  • Page 20: Timing

    TIMING - As a result of the new EU65 “Energy label” and EU66 “ Ecodesign” regulations issued by the European Commission, which came into force as from January 1st, 2015 , our products have been adapted to comply with these new requirements. All of the models complying with the energy label requirements, are equipped with new electronics including a timer device for extraction speeds control, when the air capacity exceeds 650m³/h.
  • Page 21: Maintenance

    Charcoal filters (CAP64CF) should be replaced at least every 6 months. More with heavy use. These can be purchased from your retailer or directly from Caple at www.caple.co.uk or call sales on 0117 938 1900 Tepid water and neutral detergents are recommended to clean the appliance, any abrasive products should not be used.
  • Page 22 Notes: Please keep this instruction manual for future reference Instruction manual CE1122...
  • Page 23 Notes: Please keep this instruction manual for future reference Instruction manual CE1122...
  • Page 24 Caple Service Fourth Way Avonmouth Bristol BS11 8DW t: 0117 938 7420 e: service@caple.co.uk www.caple.co.uk Contact Caple on 0117 938 7420 or for spare parts www.caple.co.uk...