Caple CCH601SS Instruction Manual

Caple CCH601SS Instruction Manual

Wall chimney hood
Hide thumbs Also See for CCH601SS:

Advertisement

Quick Links

W a l l C h i m n e y H o o d
I n s t r u c t i o n M a n u a l
CCH601SS / CCH601BK /
CCH701 / CCH901SS /
CCH901BK / CCH101
Contact Caple on 0117 938 7420 for spare parts or www.caple.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CCH601SS and is the answer not in the manual?

Questions and answers

Summary of Contents for Caple CCH601SS

  • Page 1 W a l l C h i m n e y H o o d I n s t r u c t i o n M a n u a l CCH601SS / CCH601BK / CCH701 / CCH901SS / CCH901BK / CCH101 Contact Caple on 0117 938 7420 for spare parts or www.caple.co.uk...
  • Page 2: Table Of Contents

    C O N T E N T S Introduction Safety Instructions Environmental Protection Installation Operation Care and Maintenance Troubleshooting Product Dimensions Caple Contact Details Instruction manual CCH Please keep this instruction manual for future reference...
  • Page 3: Introduction

    To ensure that you get the best results from your new extractor, we strongly suggest that you read this instruction manual thoroughly before use. If treated with care, your Caple extractor should give you years of trouble- free use. To register ownership, please ensure you complete and return the guarantee card supplied with the appliance or visit www.caple.co.uk and register here.
  • Page 4 This appliance must only be used for the purpose it is intended. Other types of use are not permitted and may prove dangerous. Caple will not be held liable for any damage caused by the incorrect use of the appliance.
  • Page 5: Safety Instructions

    I M P O R T A N T Caple cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that Caple reserve the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance.
  • Page 6 - The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels. - Regulations concerning the discharge of air have to be conformed to. - Do not flambé under the cooker hood. - Never leave frying pans unattended during use as over- heated fats and oils may catch fire.
  • Page 7 › Bed and breakfast type environments. - To avoid all risk, if the power cable is damaged, it must only be replaced by a Caple appointed engineer. - Appliances can be used by persons with reduced physical, sensory or mental capabilities or lack of...
  • Page 8 E L E C T R I C A L S H O C K H A Z A R D - Only plug this unit into a properly earthed outlet. If in doubt seek advice from a suitably qualified engineer. - Failure to follow these instructions can result in death, fire, or electrical shock.
  • Page 9: Environmental Protection

    Registration can also be completed online by visiting www.caple.co.uk. Ensure you keep your warranty card safe, you may need to show it to Caple Service together with proof of purchase. If you fail to show your warranty card you will incur all repair charges.
  • Page 10: Installation

    I N S T A L L A T I O N P R E PA R E F O R T H E I N S TA L L AT I O N : If you have an outlet to the outside, your cooker hood can be connected as per the below picture by means of an extraction duct with an interior diameter of 150mm.
  • Page 11  I N S TA L L AT I O N - D U C T E D   WA R N I N G : INSTALLATION – DUCTED                                                                                                                                                                                                                                                                                                     ...
  • Page 12   After hanging the hood on the bracket , remove the Alu Filters , mark 2 holes              After hanging the hood on the bracket, remove the grease filters, mark 2 holes inside the hood for inside the hood for safety screws .After marking , remove the hood ,drill two holes ...
  • Page 13               Drill 2×8mm holes to accommodate the plate II. Screw and tighten the plate II onto   the wall with two screws and wall plugs provided. Slide up the upper chimney and Drill 2×8mm holes to accommodate the plate II.
  • Page 14     charcoal filters must be installed. I N S TA L L AT I O N – R E C I R C U L AT I O N M O D E If you do not have an outlet to the outside, the exhaust pipe is not required (as shown in the section “Installation - ducted”), and charcoal filters must be installed.
  • Page 15 When using a charcoal filter, the extraction power may be slightly reduced. We recommend replacing these filters every 6 months. Replacement filters (CAP60CF) can be purchased directly from www.caple.co.uk.     ...
  • Page 16: Operation

                                            ...
  • Page 17: Care And Maintenance

    We recommend replacing them at least every 6 months. This extractor uses CAP60CF charcoal filters. Filters can be purchased directly from www.caple.co.uk. Instruction manual CCH 17 Please keep this instruction manual for future reference...
  • Page 18    etal clips (see fitting Solution ammed Switch off the unit and contact Caple Service. To be repaired by aged qualified service personnel only. Replace the fuse Plug in to the power supply loose again Instruction manual CCH...
  • Page 19: Troubleshooting

    Replace the charcoal is not good filter (if in recirculation mode). If the above table has not solved the problem please contact Caple Service by phone on 0117 938 7420 or by email service@caple.co.uk Instruction manual CCH 19...
  • Page 20: Product Dimensions

    P R O D U C T D I M E N S I O N S C C H 1 0 1 S I O N S C C H 9 0 1 B K C C H 9 0 1 S S C C H 7 0 1 C C H 6 0 1 B K C C H 6 0 1 S S...
  • Page 21 Instruction manual CCH 21 Please keep this instruction manual for future reference...
  • Page 22 N OT E S : Instruction manual CCH Please keep this instruction manual for future reference...
  • Page 23 N OT E S : Instruction manual CCH 23 Please keep this instruction manual for future reference...
  • Page 24: Caple Contact Details

    Caple Service Fourth Way Avonmouth T: 0117 938 1900 Bristol E: service@caple.co.uk BS11 8DW www.caple.co.uk...

This manual is also suitable for:

Cch601bkCch701Cch901ssCch901bkCch101

Table of Contents