Specifications - Siemens Milltronics L-300 Instruction Manual

Table of Contents

Advertisement

Specifications

Particle Size
• fine powder to 25 mm (1")
Product Temperature
• -40 to 85 °C (-40 to 185 °F)
Ambient Temperature
• -40 to 65 °C (-40 to 150 °F)
Accuracy
• "1 %, 33 to 100 % of design capacity; extended accuracy range with linearization
function of integrator
Repeatability
• ± 0.2 %
Capacity Range
• 100 t/h (110 STPH) to 300 t/h (330 STPH)
Maximum Volumetric Capacity
3
• 300 m
/h (10,600 ft
Maximum Tonnage
• 0 to 300 t/h (330 STPH) at 1 t/m
• Up to 0 to 500 t/h (550 STPH) at higher bulk densities
Construction
• painted mild steel flowguide and housing (cabinet) with 304 (1.4306) stainless steel
sensing plate
• optional special linings for flowguide and sensing plate
Load Cells
• construction: 50 lb stainless steel parallelogram
• excitation: 10 V DC nominal, 15 V DC maximum
• output: 2 mV / V excitation at rated load cell capacity
• non-linearity: 0.02 % of rated output
• hysteresis: 0.02 % of rated output
• non-repeatability: 0.01 % of rated output
• overload: safe 150% of rated capacity, ultimate 300% of rated capacity
Page 2
3
/h)
3
(62.4 lb/ft
Milltronics L-300 – INSTRUCTION MANUAL
3
)
7ML19985EQ01

Advertisement

Table of Contents
loading