Unless otherwise specifically agreed in writing between you and Renishaw, if you purchased CNC machine the equipment from a Renishaw company the CNC machine tools must always be operated by warranty provisions contained in Renishaw’s...
Preliminary information WEEE DIRECTIVE The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product should not be mixed with general household waste upon disposal. It is the responsibility of the end user to dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE) to enable reuse or recycling.
Refer to the machine supplier’s operating Renishaw product documentation, and to ensure instructions. that adequate guards and safety interlocks are The TS34 system must be installed by a provided. competent person, observing relevant safety Under certain circumstances the probe signal precautions.
TS34 probe system (continued) Introduction The TS34 probe is used for tool setting on CNC machining centres and is available as a rear or side exit version. For tool length measurements and broken tool detection, the tool is driven against the probe’s stylus in the Z axis.
Software routines First touch – machine spindle rev/min Software routines for tool setting are available from Renishaw for various machine controllers Rev/min for the first move against the probe stylus and are described in data sheet H-2000-2289. is calculated from a surface cutting speed of 60 m/min (197 ft/min).
Specification Principal application Tool measuring and broken tool detection on all sizes of vertical and horizontal machining centres Transmission type Hard-wired transmission Receiver/interface Recommended styli Square tip stylus (tungsten carbide, 75 Rockwell C) Weight with stylus 660 g (23.28 oz) Cable TS34R TS34S...
Page 12
1-10 Specification (continued) IP rating IPX8 (EN/IEC 60529) Storage temperature -10 °C to +70 °C (+14 °F to +158 °F) Operating temperature +5 °C to +60 °C (+41 °F to +140 °F) Note 1 Performance specification is tested at a standard test velocity of 480 mm/min (18.9 in/min) with a 35 mm stylus. Significantly higher velocity is possible depending on application requirements.
1-15 Ø45 (1.77) Ø42 (1.65) 2 off M5 grub screws for fine adjustment see page 1-15 Mount TS34 to machine Ø60 (2.36) using 3 off M4 screws Ø38 (0.59) 15 (0.59) 3 off M4 x 0.7 equispaced as shown.
NOTE: The cable screen is connected to the TS34R: 2-core 72/0.08 mm polyurethane machine via a 100 nF capacitor inside the TS34 insulated and screened cable 5.0 m (16.4 ft) long. to prevent possible earth loops. Ensure the cable Cable diameter 5.2 mm (0.20 in). Probe circuit –...
Page 15
Installation (continued) 1-13 The HSI has a maximum input voltage range of 11 Vdc to 30 Vdc. The supply is protected by a 140 mA self-resetting fuse. To reset the fuse, remove the power then identify and rectify the cause of the fault. An ‘inhibit’...
Stylus level setting 1-15 Stylus level setting Right The top surface of the stylus must be set level, front to back and right to left. The front to back stylus level is obtained by adjusting jacking screw Z, which causes the probe cable end to rise or lower, changing the Front Back...
Ensure the probe is firmly secured to its Further dismantling and repair of Renishaw mounting. equipment is a highly specialised operation, which must be carried out at authorised Renishaw The probe requires minimal maintenance as it is Service Centres. designed to operate as a permanent fixture on...
Diaphragm maintenance 1-17 1. Remove the stylus. 2. Remove the swarf deflector. 3. Use a C spanner to remove the probe’s front 2 off M3 cover. This will expose the metal eyelid seal grub screws and the inner diaphragm seal. Remove the metal eyelid and spring.
HSI probe system interface with DIN rail mounting and three terminal blocks, quick-start guide and packaging. C spanner A-2008-0332 C spanner for removing the probes front cover Publications. These can be downloaded from our web site at www.renishaw.com TS34 H-2197-8500 Installation and user’s guide: TS34 tool setting probe. H-5500-8554 Installation guide: HSI Hardwired system interface.
Page 40
Renishaw plc +44 (0)1453 524524 +44 (0)1453 524901 New Mills, Wotton-under-Edge, uk@renishaw.com Gloucestershire, GL12 8JR United Kingdom www.renishaw.com For worldwide contact details, please visit our main web site at www.renishaw.com/contact *H-2197-8500-02*...