2 INSTALLATION SPECIFICATIONS

2.1

GENERAL

1
Mount the generating set directly, without additional
vibration dampers, on a solid surface.
2
Connect the (sea) water inlet to the strainer.
3
Connect exhaust system.
4
Connect a siphon breaker or 'air vent' into the cooling
circuit, if necessary.
5
Connect 'fuel supply line' to the water separator/ fuel
filter.
6
Connect 'fuel return line' to the fuel tank.
7
Connect remote panel (just plug in).
8
Connect the AC cable from the AC box to the power
source selector.
9
Connect plus and minus from the 12V starter battery
to the battery cables.
10 Install a WhisperPower battery charger. (optional).
2.2

COMMISSION TABLE

1
Check if a siphon breaker (air vent) is necessary and
has been installed.
2
Open the seawater inlet valve and check all water
connections. Check if the strainer is installed on or
just above the seawater level.
3
Check if the exhaust system is properly installed.
Check maximum length of exhaust hose, diameter of
exhaust hose, position of the water lock, maximum lift.
Also check the minimum required height of 60 cm
above sea level of the exhaust loop (goose neck).
4
Open the seawater outlet valve and check all water
connections.
5
Check the AC cables and the grounding.
6
Check if an AC breaker is installed before or after the
power source selector. When there is only a circuit
breaker, use it to disconnect the generating set from
the grid.
EN / M-SQ12/16 - Three Phase / July 2016
7
Check all DC connections, check if the battery switch/
circuit breaker is closed.
8
Open the fuel valve. Check if there are no air leaks in
the fuel supply line, and check if the lift of the fuel is
less than 1 meter. Check if there is no air in the water
fuel separator.
9
Check if the air intake in the canopy is not blocked.
10 Check the oil level and colour of the oil. Check the
coolant level
11 To bleed the fuel system:
M-SQ12 Three Phase: push the "Start" button on
the local control (not on the remote panel) and
hold at least 5 seconds and as long as necessary
to bleed the system.
M-SQ16 Three Phase: use the manual pump by
turning the cap loose and pumping as long as
necessary to bleed the system. See chapter
4.2.2. of the user's manual.
12 Start the engine by pushing the start button
13 Check when the generating set is running, the delay
of 5 to 10 seconds in the power source selector
transfer.
14 Check voltage and frequency under 'no load'
conditions.
15 Check voltage and frequency under 'full load'
conditions.
16 Check if the battery charger of the generating set is
working (max. 14.5 Volt).
17 Close the sound shield and check the noise level.
18 Stop the generating set and check the engine again
for leakages of oil, fuel or water.
Installation
checklist
available
www.whisperpower.com.
Commissioning
form
available
www.whisperpower.com.
INSTALLATION SPECIFICATIONS
on
our
website:
on
our
website:
19