  • Page 1 PROEL MS 32 PROGRAMMABLE MIDI SENDER OWNER’S MANUAL...
  • Page 2: Table Of Contents

    INDEX SPECIFICATIONS........................3 MEMORY STRUCTURE ......................4 MS 32 FRONT AND REAR VIEW ..................... 5 POWER ON..........................6 GLOBAL PARAMETERS......................7 POWER-ON NAME : ..............................7 POWER-ON SET & PATCH RECALL : .........................8 BASIC RX MIDI CHANNEL : ..........................9 FOOT CONTROLLER 1 CALIBRATION :......................10 FOOT CONTROLLER 2 CALIBRATION :......................11...
  • Page 3: Specifications

    9. "A"- yCC (0~120 at value 0~127/Off) 10. "B"- CC 00 (0~127/Off) 11. "B"- CC 32 (0~127/Off) 12. "B"- PC (1~128/Off) 13. "B"- xCC (0~120 at value 0~127/Off) 14. "B"- yCC (0~120 at value 0~127/Off Proel MS 32 Owner's Manual...
  • Page 4: Memory Structure

    $ SDUW ;&& YDOXH % SDUW ;&& ;; YDOXH "0~127/Off" "0~127/Off" $ SDUW <&& DVVLJQ WR &RQWURO &KDQJH % SDUW <&& DVVLJQ WR &RQWURO &KDQJH "0~120" "0~120" % SDUW <&& YDOXH $ SDUW <&& YDOXH "0~127/Off" "0~127/Off" Proel MS 32 Owner's Manual...
  • Page 5: Ms 32 Front And Rear View

    MS 32 FRONT AND REAR VIEW Proel MS 32 Owner's Manual...
  • Page 6: Power On

    When switched on the MS32 displays 3 subsequent screen shots before displaying the MASTER screen shot; first screen shot: PROEL MIDISender second screen shot: MS-32 User Name third screen shot: 00 Basic Ch = 16 MASTER screen shot in the Patch mode: 0 *FACTORY0* >0 Proel MS 32 Owner's Manual...
  • Page 7: Global Parameters

    " switches ( allow you to choose the character to be inserted. (Keeping the switch pressed the characters will shift automatically). Æ Æ Use the " 5" and "6 " switches ( ‚‚‚ Character Cursor Proel MS 32 Owner's Manual...
  • Page 8: Power-On Set & Patch Recall

    (from 0 to 9) to be inserted. (Keeping the switch pressed the characters will shift automatically). Æ Æ Use the " 5" and "6 " switches ( ‚‚‚ to move the cursor from SET to PATCH. Value Cursor Proel MS 32 Owner's Manual...
  • Page 9: Basic Rx Midi Channel

    Omni On) to be inserted and the On/Off condition. (Keeping the switch pressed the characters will shift automatically). Æ Æ Use the " 5" and "6 " switches ( ‚‚‚ to move the cursor from channel number to On/Off Value Cursor Proel MS 32 Owner's Manual...
  • Page 10: Foot Controller 1 Calibration

    Position the Foot Pedal inserted in the FC1 socket at minimum value and press the START/STOP switch; Position the Foot Pedal at maximum value Æ Æ and press the START/STOP switch ( OK is displayed twice on the screen. Proel MS 32 Owner's Manual...
  • Page 11: Foot Controller 2 Calibration

    Position the Foot Pedal inserted in the FC2 socket at minimum value and press the START/STOP switch; Position the Foot Pedal at maximum value Æ Æ and press the START/STOP ( ) switch. OK is displayed twice on the screen. Proel MS 32 Owner's Manual...
  • Page 12: Continue Switch Assignment

    ) to confirm the data and exit from "GLOBAL" parameter programming. Continue=Cnt CONTINUE SWITCH ASSIGNMENT: Continue=Cnt Æ Æ Press the "10 " and "10 " switches ( to select the Cnt (Continue), PBS (Patch Bay Switches) or Cnt+PBS options. Value Proel MS 32 Owner's Manual...
  • Page 13: Global Parameters Flow Chart

    GLOBAL PARAMETERS FLOW CHART : POWER-ON NAME CONTINUE POWER-ON SWITCH ASSIGN SET & PATCH EXIT RECALL GLOBAL PARAMETER FC 2 BASIC CALIBRATION RX MIDI CHANNEL FC 1 CALIBRATION "SELECT/CHANNEL" Switch "CC XX/CONTINUE" Switch Proel MS 32 Owner's Manual...
  • Page 14: Write Global Parameter

    When using the WRITE switch the display will show the following message: Write Complete ! and will go back to the PATCH MASTER screen shot after some seconds: 0 *FACTORY0* >0 Proel MS 32 Owner's Manual...
  • Page 15: Mode

    LEDs placed beside the display: - PATCH - FREE - SET Keep the MODE/WRITE switch pressed for some seconds to enter the functions WRITE SET or WRITE PATCH. Proel MS 32 Owner's Manual...
  • Page 16: Set Mode

    3 and 7 press: the switch no. 3 the switch no. 7 The pedalboard will now recall alternatively the sets no. 3 and 7 by pressing only switch no 7. Proel MS 32 Owner's Manual...
  • Page 17: Start/Stop And Continue Functions

    NOTE: Remember to set in LOCAL (INTERNAL CLOCK, REMOTE CONTROL, etc.) all the equipments (computer, module sequencer, etc.) connected via Midi to the MS 32 if you want to control the START/STOP/CONTINUE functions from the pedalboard (note that no MIDI CLOCK signal is sent via midi from the MS-32).
  • Page 18 - the "CCXXX/CONTINUE" switch ( ) to confirm the data and pass to the ‚‚‚ display/modification of the first "SET" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to exit from "SET" parameter programming. Name: *FACTORY0* Proel MS 32 Owner's Manual...
  • Page 19: Set Name

    ) to confirm the data and pass to the ‚‚‚ display/modification of the following "SET" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "SET" parameter programming. Song Sel: 0 Of Proel MS 32 Owner's Manual...
  • Page 20: Song Select

    ) to confirm the data and pass to the ‚‚‚ display/modification of the following "SET" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "SET" parameter programming. A PartMIDI Ch Proel MS 32 Owner's Manual...
  • Page 21: A" Part Tx Midi Channel

    ) to confirm the data and pass to the ‚‚‚ display/modification of the following "SET" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "SET" parameter programming. B PartMIDI Ch Proel MS 32 Owner's Manual...
  • Page 22: B" Part Tx Midi Channel

    ) to confirm the data and go back to the ‚‚‚ display/modification of the first "SET" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "SET" parameter programming. Name: *FACTORY0* Proel MS 32 Owner's Manual...
  • Page 23: Set Parameters Flow Chart

    SET PARAMETERS FLOW CHART: NAME "B" PART EXIT SONG SELECT TX MIDI PARAMETER CHANNEL "A" PART TX MIDI CHANNEL "SELECT/CHANNEL" switch "CC XXX/CONTINUE" switch Proel MS 32 Owner's Manual...
  • Page 24: Write Set Memory

    Exit (no write) Write Set Number lost. When using the WRITE switch, the display will show the following message: Write Complete ! and will go back to the SET MASTER screen shot after some seconds: Proel MS 32 Owner's Manual...
  • Page 25: Patch Mode

    PATCH number of the current SET. All the patch parameters are recalled and transmitted via Midi: Example: when the switch no. 3 is pressed, the display will show: 0 *FACTORY0* >3 SET Number SET Name PATCH Number Proel MS 32 Owner's Manual...
  • Page 26: Start/Stop And Continue Functions

    NOTE: Remember to set in LOCAL (INTERNAL CLOCK, REMOTE CONTROL, etc.) all the equipments (computer,module sequencer, etc.) connected via Midi to the MS 32 if you want to control the START/STOP/CONTINUE functions from the pedalboard (note that no MIDI CLOCK signal is sent via midi from the MS-32).
  • Page 27: Edit Patch Parameters

    - the "CCXXX/CONTINUE" switch ( ) to display or modify the first “PATCH” parameter or ‚‚‚ Æ Æ - the "SELECT/CHANNEL" switch ( ) to exit from “PATCH” parameter programming. FC1 to 7 AB On Proel MS 32 Owner's Manual...
  • Page 28: Fc1 Assign

    - the "CCXXX/CONTINUE" switch ( ) to confirm the data and display/modify the following ‚‚‚ “PATCH” parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from “PATCH” parameter programming. 0 Mx127 Proel MS 32 Owner's Manual...
  • Page 29: Fc1 Range

    ) to confirm the data and display/modify the following ‚‚‚ “PATCH” parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from “PATCH” parameter programming. FC2 to 11 AB On Proel MS 32 Owner's Manual...
  • Page 30: Fc2 Assign

    - the "CCXXX/CONTINUE" switch ( ) to confirm the data and display/modify the following ‚‚‚ “PATCH” parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from “PATCH” parameter programming. 0 Mx127 Proel MS 32 Owner's Manual...
  • Page 31: Fc2 Range

    - the "CCXXX/CONTINUE" switch ( ) to confirm the data and display/modify the following ‚‚‚ “PATCH” parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from “PATCH” parameter programming. FC1/2 Link Proel MS 32 Owner's Manual...
  • Page 32: Fc1/2 Link

    - the "CCXXX/CONTINUE" switch ( ) to confirm the data and display/modify the following ‚‚‚ “PATCH” parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from “PATCH” parameter programming. PBS1 Of PBS2 Proel MS 32 Owner's Manual...
  • Page 33: Patch Bay Switch 1-2

    - the "CCXXX/CONTINUE" switch ( ) to confirm the data and display/modify the following ‚‚‚ "PATCH" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "PATCH" parameter programming. PBS3 Of PBS4 Proel MS 32 Owner's Manual...
  • Page 34: Patch Bay Switch 3-4

    ) to confirm the data and display/modify the following "PATCH" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "PATCH" parameter ‚‚‚ programming. A c0= Of c32= 0f Proel MS 32 Owner's Manual...
  • Page 35: A Channel Bank Select Cc00 & Cc32

    - the "CCXXX/CONTINUE" switch ( ) to confirm the data and display/modify the following ‚‚‚ "PATCH" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "PATCH" parameter programming. PC = Proel MS 32 Owner's Manual...
  • Page 36: A Channel Program Change

    - the "CCXXX/CONTINUE" switch ( ) to confirm the data and display/modify the following ‚‚‚ "PATCH" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "PATCH" parameter programming. 91 = Proel MS 32 Owner's Manual...
  • Page 37: A Channel Programmable "X" Control Change

    - the "CCXXX/CONTINUE" switch ( ) to confirm the data and display/modify the following ‚‚‚ "PATCH" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "PATCH" parameter programming. 93 = Proel MS 32 Owner's Manual...
  • Page 38: A Channel Programmable "Y" Control Change

    ) to confirm the data and display/modify the following ‚‚‚ "PATCH" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "PATCH" parameter programming. B c0= Of c32= 0f Proel MS 32 Owner's Manual...
  • Page 39: B Channel Bank Select Cc00 & Cc32

    - the "CCXXX/CONTINUE" switch ( ) to confirm the data and display/modify the following ‚‚‚ "PATCH" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "PATCH" parameter programming. PC = Proel MS 32 Owner's Manual...
  • Page 40: B Channel Program Change

    - the "CC XXX/CONTINUE" switch ( ) to confirm the data and display/modify the following ‚‚‚ "PATCH" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "PATCH" parameter programming. 91 = Proel MS 32 Owner's Manual...
  • Page 41: B Channel Programmable "X" Control Change

    - the "CCXXX/CONTINUE" switch ( ) to confirm the data and display/modify the following ‚‚‚ "PATCH" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "PATCH" parameter programming. 93 = Proel MS 32 Owner's Manual...
  • Page 42: B Channel Programmable "Y" Control Change

    ) to confirm the data and go back to the ‚‚‚ display/modification of the first "PATCH" parameter or Æ Æ - the "SELECT/CHANNEL" switch ( ) to confirm the data and exit from "PATCH" parameter programming. FC1 to 7 AB On Proel MS 32 Owner's Manual...
  • Page 43: Patch Parameters Flow Chart

    B CC0 & CC32 EXIT PATCH PARAMETER FC 1/2 LINK A yControl Change A xControl Change PBS 1 & PBS 2 PBS 3 & PBS 4 A Program Change A CC0 & CC32 "SELECT/CHANNEL" Switch "CC XXX/CONTINUE" Switch Proel MS 32 Owner's Manual...
  • Page 44: Write Patch Memory

    Patch Number previously modified parameters will be lost. When using the WRITE switch, the display will show: Write Complete ! and after some seconds will go back to the PATCH MASTER screen shot: 0 *FACTORY0* >0 Proel MS 32 Owner's Manual...
  • Page 45: Factory Reset & Midi Data Dump

    Factory Reset or Data Midi Dump functions. Æ Æ Press the START/STOP switch ( ) to ‚‚‚ exit from the Factory/Dump screen shot and go back to the main menu. Exit Factory Reset Data Midi Dump Proel MS 32 Owner's Manual...
  • Page 46: Factory Reset

    - If the Continue switch is pressed, the pedalboard will display: Loading Factory! and go back to the main screen shots. - Press Start/Stop to exit from the "FACTORY" function; the pedalboard will display the main screen shots. Proel MS 32 Owner's Manual...
  • Page 47: Data Midi Dump (Sending)

    ) to exit from the "DUMP" function. ‚‚‚ Dump All Cont? - If the Continue switch is pressed, the pedalboard will show: Sending Dump.. ! When the data transmission is completed, the display will go back to the main screen shots.. Proel MS 32 Owner's Manual...
  • Page 48: Data Midi Dump (Receiving)

    This means the data reception was not successfully completed; it is necessary to switch the pedalboard off and activate the Factory Reset functioned described at pages 45/46. Retry the loading procedure controlling the dump speed and slowing it down if necessary. Proel MS 32 Owner's Manual...
  • Page 49: Free Mode

    Press the pedalboard switches to choose the message shown above the switch number. The pedalboard goes automatically back to the main menu of the Free mode showing the selected Midi message: Ch=1 CC 07= Midi Channel Value Type of Message START or CONTINUE selected Proel MS 32 Owner's Manual...
  • Page 50: The Possible Midi Messages

    Ch = 1 CC 07= CC 10 switch Ch = 1 CC 10= CC YY switch 0 Continue? Ch = 1 CC CC 11 switch Ch = 1 CC 11= CC 16 switch Ch = 1 CC 16= Proel MS 32 Owner's Manual...
  • Page 51 CC 91 switch Ch = 1 CC 91= CC 93 switch Ch = 1 CC 93= CC 94 switch Ch = 1 CC 94= SONG switch Ch = 1 Song = Proel MS 32 Owner's Manual...
  • Page 52: Midi Message Transmission

    It is now possible to select the value to be sent through the above-described procedure. NOTE : In the FREE mode the Foot Controllers 1 and 2 send the values of the selected midi messages. Proel MS 32 Owner's Manual...
  • Page 53: Midi Channel/ Patch Bay Switches

    1on 2on 3on 4on Press the switches from 1 to 4 to select alternatively the On or Off condition for the corresponding PATCH BAY switches. Press the "SELECT/CHANNEL" switch to exit and go back to the FREE mode. Proel MS 32 Owner's Manual...
  • Page 54: Factory Setup & Range

    % SDUW ;&& DVVLJQ WR &RQWURO &KDQJH "0~120" 0~120 On/Of % SDUW ;&& ;; YDOXH "0~127/Off" 40 Of 0~127 On/Of % SDUW <&& DVVLJQ WR &RQWURO &KDQJH "0~120" 0~120 On/Of % SDUW <&& YDOXH "0~127/Off" 0 Of 0~127 On/Of Proel MS 32 Owner's Manual...
  • Page 55: Technical Specifications

    LIMITATIONS: The MS-32 is limited only to the transmission of the messages listed on page 3 of the owner’s manual. Proel S.p.A. is not responsible for a different use. This product responds to the 83/33 E.C. directives concerning the elettro-...
  • Page 56: Spare Parts & Optionals

    Cod. PPSM16 OPTIONALS Cod. RLD700 PROEL/DIN 7 PIN CABLE: PROEL/DIN 5 PIN CABLE: Cod. SH120 Cod. PVP16L PROEL/FOOT CONTROLLER: PROEL/PATCH BAY MONO CABLE: Cod. ROAD100LU5 Cod. 92MNIM32 PROEL/OWNER’S MANUAL: PROEL/HARD CASE FOR MS32: Cod. CPMS32 Proel MS 32 Owner's Manual...
  • Page 57 PROEL S.p.A. Zona Artigianale 64027 Sant’Omero (TE) – Italy Tel: +39 0861 81241 Fax: +39 0861 887862 Proel web site: www.proelgroup.com E-mail: info@proelgroup.com Copyright © 1999 PROEL S.p.A. Manufactured and printed in Italy Specifiche e caratteristiche possono variare senza alcuna notifica...