5-7 Capacitance Measurement

1)
Select the " Function rotary switch " ( 3-10, Fig. 1 ) to
the "
2)
Connect the tested capacitor to " Input terminals " directly.
* If the measured capacity existing the polarity, then
should connect the " + " polarity of the measured
capacitor to the "
connect the " - " polarity of the measured
capacitor to the " COM " terminal ( 3-12, Fig. 1 ),
* Full discharge the measured capacitor before the
make the measurement.
3)
When LCD show the " AUTO " marker, the meter is
under the " auto range " mode. Meter will select the
suitable measurement range automatically.
4)
Capacitance measurement mode, no manual functions,
" Range button " ( 3-6 Fig. 1 ) is invalid.

5-8 Inductance Measurement

1)
Connect BLACK test lead into " COM " terminal ( 3-12,
Fig. 1 ).
2)
Connect RED test lead into "
3)
Select the " Function rotary switch " ( 3-10, Fig. 1 ) to
the "
4)
When LCD show the " AUTO " marker, the meter is
under the " auto range " mode. Meter will select the
suitable measurement range automatically.
5)
Inductance measurement mode, no manual functions,
" Range button " ( 3-6 Fig. 1 ) is invalid.
" position.
" position.
" terminal ( 3-11, Fig. 1 ),
" terminal ( 3-11, Fig. 1 ).