OPERATION INSTRUCTIONS

Power On
Press Power button (1) to turn on the monitor after placing 4 AA batteries
into the battery compartment (take care to observe correct polarity) or AC
adapter plug into the DC socket. CO
warm up.
WarmUp
This lasts approximately 1 min before WARMUP disappears; none of the
functions will respond during warm up.
Normal Operation
After warm up, the monitor stabilizes and displays CO
Display which remain visible at all times.
Temp and Ventilation Rates (Lower Display)
Use the Up/Down button to scroll through Temperature and Ventilation
Modes.
When pressing the Up button, the lower display goes through the following
sequence:
Temp °C-> Temp°F-> Vent Rates lps-> Vent Rate cfm/p
*Note:
lps refers to Litres Per Second Per Person;
cfm/p refers to Cubic Feet Per Minute Per Person
This function assumes that each person exhales 300 cc of CO
and calculates the rate of ventilation of external air required to achieve
equilibrium at the measured CO
readings will show after 15 seconds of
2
level.
2
readings on its Upper
2
every minute
2