Additional Parameter Settings - Siemens SINAMICS DCM Compact User Manual

Dc converter, 12-pulse applications
Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

3.3.2

Additional parameter settings

Table 3- 2
Parameter settings on the master converter and on the slave converter:
Parameter
p51799
Mode of operation
p51800
Position in the topology
p51801
Amount of send data
p51802
Number of power units
p51803
n+m mode
p51804[..]
Send data
p51805
Bus terminator
p51806
Station address
p51807
Telegram failure time
p50082
Field operating mode
p50076[..]
Reduction in the rated unit DC cur-
rent
3)
p50078[..]
Rated value for supply voltage
p50100
Rated motor current
p50357
Threshold for interrupted tachometer
1)
If the number of power units that are ready to operate for n+m operation is less than the value set in p51802, then fault
message F60044 is output, followed by shutdown (OFF2).
2)
= 1 at the two outermost units (= at the physical ends of the bus line)
= 0 on all of the other units
3)
Note: In conjunction with r50072[..], ensure that p50076[..] is correctly set, as described in the List Manual under
p50076[..].
12-pulse applications
Compact User Manual, 09/2015, A5E34871844H
Master
0, 21 or 22
21 (12-pulse master)
0,4,8,12,16
≥ 2
1)
0 or 1
Application-specific
0 or 1
2)
Unique address (1..16)
Recommended, 0.1 s
≠ 0 (application-specific)
Application-specific
Application-specific
Rated motor cur-
rent/number of SINAMICS
DCMs
Application-specific
12-pulse parallel connection
3.3 Commissioning
Slave or parallel devices
The same as on the master
22 (12-pulse slave)
23 (devices connected in parallel to
the master)
24 (devices connected in parallel to
the slave)
must be the same for both partici-
pants
≥ 2
the same as for the master
the same as for the master
0 or 1
2)
The same as for the master (1..16)
Recommended, 0.1 s
0 (no field)
The same as on the master
The same as on the master
The same as on the master
100% (tachometer interruption
monitoring not active)
23

Advertisement

Table of Contents
loading

Table of Contents