ESAB MobileFeed 301 AVS Instruction Manual page 18

Hide thumbs Also See for MobileFeed 301 AVS:
Table of Contents

Advertisement

5 OPERATION
1.
Main fuse, 10 A
2.
Circuit breaker, 7 A
Circuit breaker, 7 A
This resettable 7 A circuit breaker, in series with motor armature, protects the control board
from damage if the motor is stalled.
Jog/Purge switch
JOG is used when you need to feed the wire without welding voltage being applied. The wire
is fed at the set speed for as long as the switch is pushed.
PURGE is used when measuring the gas flow or to flush any air or moisture from the gas
hoses before welding starts. The gas flows as long as the switch is pushed. There is no need
for welding voltage or wire feed start.
If the wire has been threaded through torch and contact tip, simply operate the jog button or
cut off wire, as required, so that the wire extends about 1/2" beyond the end of the torch
nozzle.
CC/CV switch
The CC/CV switch is used to set CC or CV mode. CC mode is used for constant current
power sources. CV mode for constant voltage power sources. The selected mode also has
impact on the functions of the wire feeder as shown below:
Mode
Display
CC
Wire feed speed and arc voltage
shown
CV
Wire feed speed shown
0558 012 634
3.
Jog/purge switch
4.
CC/CV switch
Knob for setting the wire feed speed
Controls the arc voltage / Wire speed
feed increase with increased voltage
Controls the welding current
- 18 -
© ESAB AB 2016

Advertisement

Table of Contents
loading

Table of Contents