Husqvarna 326 E Workshop Manual page 14

Hide thumbs Also See for 326 E:
Table of Contents

Advertisement

Electrical system
If no spark occurs, disconnect the stop
switch.
Replace the switch if necessary.
Still no spark?
Check the ignition cable's connection to
the spark plug cover.
Pry off the metal washer and lift off the
heat guard.
Pull away the ignition lead from the spark
plug cover.
Check that the connection between the
ignition lead and the contact coil is not
burnt.
If this is the case, cut off the damaged
section.
Use pliers no. 502 50 06-01 to make a
hole in the ignition lead.
502 50 06-01
If no spark occurs even now, remove the
short-circuit cable from the connection
point in the carburettor compartment.
If the plug now sparks, the fault is either in
the stop switch or the short-circuit cable.
Change the switch as needed and check
to see if the cable insulation is damaged.
Still no spark?
Check the spark plug connection.
1. Pry off the metal washer using a small
screwdriver and lift off the heat guard
from the spark plug connection.
2. Pull away the ignition lead from the
spark plug cover with a twisting move-
ment.
TIP!
Lubricate the ignition lead with a few
drops of oil.
3. Check the connection between the
ignition lead and the contact coil. Cut
off a piece of the ignition lead to make
a satisfactory connection.
When a part of the ignition lead has been
cut off it helps to use the pliers no. 502 50
06-01 to make a hole in the ignition lead to
fi t the contact coil.
NOTE!
It is important that the tip of the
contact coil hits the centre of the
ignition lead to prevent sparking.
2
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

326 ls327 es327 rjx327 ldx327 ls327 rx

Table of Contents