Hartridge HK900 Operating Manual page 15

All makes common rail injector test kit avm2
Table of Contents

Advertisement

HARTRIDGE LIMITED
Once the AE31 and AE32 boxes have been fitted together, hang on the right hand side of the test
bench and connect as follows (the numbers in brackets refer to Figures 2.2 and 2.3 above):
CAUTION! The voltage selector switch must be set to the correct setting for your local single
phase voltage (120/240V).
1.
Set the voltage selector switch (11) to the correct value then plug in the single phase power lead.
2.
Connect flying lead (8) to the spare socket on the right hand side of the AE31 unit.
3.
Connect the red D plug on loom A089E956 to socket (9) on the AE32. Plug the other end of this
loom into EXT2 on the rear of the AVM2. Plug the AE31 comms loom A086E913 into the spare
flying socket on this new loom.
4.
Connect the flying lead (7) to the response time unit on the fixture.
You are now ready to connect the main injector drive lead to socket (3) and the resistance cable to
socket (4). These cables will depend on the injector type you are testing; see TIB195/11.
HL030(EN), Issue 1, June 2005
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.