MDX1+ MDX1 - Power Power MDX0+ MDX0 - MDX2+ MDX2 - MDX3 - MDX3+ TP-Ports TP-Ports Function Function +48V DC +48V DC +48V DC +48V DC FAULT FAULT OCTOPUS OS32-081602T6T6... OCTOPUS OS32-081602O6O6... OCTOPUS 8M/16M/24M/OS32 Technical Support Release 10 05/2012 https://hirschmann-support.belden.eu.com...
Page 2
In addition, we refer to the conditions of use specified in the license contract. You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com). Printed in Germany Hirschmann Automation and Control GmbH Stuttgarter Str.
Contents Safety instructions About this Manual Legend Device description General device description Description of the device variants 1.2.1 Devices without Power over Ethernet 1.2.2 Devices with Power over Ethernet Assembly and start-up Installing the device 2.1.1 Unpacking and checking 2.1.2 Installing the SFP modules (optional) 2.1.3 Connecting the connector for supply voltage and signal contact 2.1.4 Installing the device and grounding...
Safety instructions Important Information Notice: Read these instructions carefully, and look at the equipment to become familiar with the device before trying to install, operate, or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
Page 6
Certified usage The device may only be employed for the purposes described in the catalog and technical description, and only in conjunction with external devices and components recommended or approved by the manufacturer. The product can only be operated cor- rectly and safely if it is transported, stored, installed and assembled pro- perly and correctly.
Page 7
The supply voltage is electrically isolated from the housing. Use undamaged parts. Only use voltage supply cables with the permitted diameter specified by the manufacturer of the right angled cable socket. Relevant for North America: Devices without Power-over-Ethernet (PoE) may only be connected to a supply voltage of class 2 that fulfills the requirements of the National Electrical Code, Table 11(b).
Environment The device may only be operated at the specified surrounding air temperature (temperature of the surrounding air at a distance of up to 5 cm (1.97 in) from the device) and relative air humidity specified in the technical data. ...
Page 9
Guideline for standardizing the regulations of member states relating to radio interference from motor vehicles. Certified devices are marked with an e1 type approval indicator. (Relevant for OCTOPUS 8M-8PoE, OCTOPUS 8M-6PoE, OCTOPUS 16M-8PoE, OCTOPUS 16M-8PoE-2FX, OCTOPUS 24M-8PoE) Rule No.10 of the Economic Commission for Europe (ECE): Devices with a certification are labelled with the E1 type-approval mark.
Page 10
In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address: Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany Tel.: +49 (0)1805 14-1538 The product can be used in the industrial sector.
Page 11
Maintenance When designing this device, Hirschmann was largely able to forego using parts that are subject to waer and tear. The parts subject to wear are designed to last longer than the lifetime of the product when it is operated properly.
About this Manual The “Installation” user manual contains a device description, safety instructions, a description of the display, and the other information that you need to install the device. The following manuals are available as PDF files on the CD-ROM supplied: ...
Device description General device description The OCTOPUS 8M/16M/24M/OS32 devices are designed for the special requirements of industrial automation. They meet the relevant industry standards, provide very high operational reliability, even under extreme conditions, and also provide long-term reliability and flexibility. The devices allow you to set up switched industrial Ethernet networks that conform to the IEEE 802.3 standard in line and ring structures.
SNMP 802.1x port authentication Real Time Clock The Hirschmann network components help you ensure continuous communication across all levels of the company network. Description of the device variants 1.2.1 Devices without Power over Ethernet The following device variants provide 8 to 24 10BASE-T/100BASE-TX ports (RJ45 connections) for connecting network segments or terminal devices: ...
Page 15
Number of FX Number of Gigabit- PoE-capable ports TX ports capable TX TX ports ports included included OCTOPUS 8M-8PoE — — (ports 1 to 8) OCTOPUS 8M-6PoE — — 6 (ports 1 to 3 and 5 to 7) OCTOPUS 16M-8PoE —...
Assembly and start-up The devices have been developed for practical application in a harsh industrial environment. On delivery, the device is ready for operation. The following procedure has been proven to be successful for the assembly of the device: Unpacking and checking ...
The supply voltage and the signal contact are connected by means of a 5-pin M12 connector (A coding, e.g. ELWIKA 5012 PG7 from Hirschmann, included in the delivery). Note: The permitted cable diameter for connector ELWIKA 5012 PG7 is 4 mm to 6 mm. To ensure the watertightness of the OCTOPUS 8M/16M/ 24M/OS32 device, only use voltage supply cables with a diameter within the specified range.
Page 19
The PoE supply voltage for the OCTOPUS ...PoE... and OS32... devices is connected via a 5-pin M12 connector (A coding, e.g. ELWIKA 5012 PG7 from Hirschmann, supplied). The OCTOPUS ... PoE... and OS32... devices are supplied with PoE voltage (48 V DC safety low voltage) via an external power supply unit.
Figure Function + 48 V DC (1) Fault 0 V DC + 48 V DC (2) Fault Table 3: Pin assignment of the 5-pin M12 socket for connecting the PoE supply voltage and the signal contact “FAULT” signal contact ...
Page 21
Note: Dust, moisture and fire protection is only achieved under the following conditions: All the unused connections and ports are closed with locking screws. (see page 40 “Accessories”) All the connectors and cables connected also fulfill protection class IP67 and IP54.
Page 22
Figure 3: Dimensions of the following devices: - OCTOPUS 8M (shown in fig.) - OCTOPUS 8M Train - OCTOPUS 8M-6PoE - OCTOPUS 8M-8PoE OCTOPUS 8M/16M/24M/OS32 Release 10 05/2012...
Grounding the device The device is grounded via the separate ground screw. Use toothed washers to ensure good electrical conductivity at the connection. Note: The shielding ground of the connectable twisted pair lines is connected to the housing as a conductor. 2.1.5 Connecting the supply voltage, starting up...
Page 26
Connect the cable shield to the connector housing. Seal all unused ports with locking screws. (see page 40 “Accessories”) 10/100 Mbit/s twisted pair connection for PoE (4-pin M12 sockets) 10/100 Mbit/s TP PoE ports enable the connection of terminal devices or independent network segments according to the IEEE 802.3 10BASE-T/ 100BASE-TX and IEEE 802.3af (Power over Ethernet) standards.
Page 27
10/100/1000 Mbit/s twisted pair connection (8-pin M12 connector) 10/100/1000 Mbit/s TP ports enable the connection of terminal devices or independent network segments according to the IEEE 802.3 10BASE-T/ 100BASE-TX/1000BASE-T standard. These ports support: Autonegotiation (10/100/1000 Mbit/s half and full duplex) ...
Page 28
The patch cables for operating the device are shown in table Patch cables Wire pairs M12 4-pin on M12 4-pin, crossed 1 (TX+) – 2 (RX+) (MDI to MDI) 2 (RX+) – 1 (TX+) 3 (TX−) – 4 (RX−) 4 (RX−) – 3 (TX−) M12 4-pin on M12 4-pin, 1:1 1 (TX+) –...
100/1000 Mbit/s FO connection (SFP, IP67-V1 connector based on IEC 61076-3-106, variant 1) 100/1000 Mbit/s F/O ports enable the connection of terminal devices or independent network segments according to the IEEE 802.3 100BASE- FX/1000BASE-SX/1000BASE-LX standard. These ports support: Full duplex mode State on delivery: ...
Display Color Activity Meaning Supply voltage 1 Green Lights up The supply voltage is on. None The supply voltage is too low. Supply voltage 2 Green Lights up The supply voltage is on. None The supply voltage is too low. FAULT Signal contact None Signal contact is closed, it is not reporting...
Configuration via DHCP Option 82 Auto Configuration Adapter Further information on the basic settings of the device can be found in the “Basic Configuration” user manual on the CD ROM. Default settings IP address: The device looks for the IP address using DHCP ...
Page 32
Technical Data chapter (see page 40). Note: Available as an accessory for certain Hirschmann devices, AutoConfiguration Adapter ACA11-M12 is not designed to be used with OCTOPUS 8M/16M/24M/OS32 devices. Always use the ACA21-M12 if you want to use an AutoConfiguration...
Disassembling the SFP modules (optional) To disassemble SFP modules on OS32 devices, you require the SFP mounting tool available as an accessory (see fig. Figure 8: SFP mounting tool 1 – mounting side 2 – barbed hooks 3 – disassembly side ...
261 × 189 × 70 mm OCTOPUS 24M..., OCTOPUS OS32-0816... 338 × 189 × 70 mm Weight OCTOPUS 8M 1,310 g OCTOPUS 8M Train OCTOPUS 8M-8PoE OCTOPUS 8M-6PoE OCTOPUS 16M 1,920 g OCTOPUS 16M Train OCTOPUS 16M-8PoE OCTOPUS 16M-2FX 2,000 g OCTOPUS 16M-8PoE-2FX OCTOPUS OS32-0808...
Page 35
Insulation voltage OCTOPUS ... (without PoE or 800 V DC between operating Train) Protective elements limit the insulation voltage connections voltage to 90 V DC (1 mA) and housing OCTOPUS ... Train 707 V DC OCTOPUS...PoE... und OS32-... 2,250 V DC “FAULT”...
Page 36
EMC and immunity EMC compliance – IEC/EN 61000-6-2:2005 EMI TYPE tests, test acc. to: IEC/EN 61000-4-2 Electrostatic discharge Contact discharge 6 kV Air discharge 8 kV IEC/EN 61000-4-3 Electromagnetic field 80 MHz ... 2700 MHz 10 V/m IEC/EN 61000-4-4 Fast transients (burst) Power line 4 kV Data line...
Page 37
Connec- Wave- Fiber System Example Fiber tion length attenuati for F/O line attenuation dispersion length MicroFX MM 1300 nm 50/125 µm 0-8 dB 0-5 km 1.0 dB/km 800 MHz*km MircoFX MM 1300 nm 62.5/125 µm 0-11 dB 0-4 km 1.0 dB/km 500 MHz*km Table 11: FO port 100BASE-FX (MicroFX) a.
Page 41
The following accessory parts are unsealed: RJ45 adapters Terminal cable Name Operating Order number temperature (chassis) Pocket Guide 280 710-851 AutoConfiguration Adapter ACA21-M12 943 913-001 Terminal cable 943 902-001 Connector ELWIKA 5012 PG7 933 175-100 (5-pin M12 socket for supply voltage and signal contact) Field-attachable 5-pin M12 socket RKC5/Duo...
Page 42
The device has a certification based on a specific standard only if the certification indicator appears on the housing. However, with the exception of Germanischer Lloyd, ship certifications are only included in the product information under www.hirschmann.com. OCTOPUS 8M/16M/24M/OS32 Release 10 05/2012...
Further Support Technical Questions For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You will find the addresses of our partners on the Internet at http://www.hirschmann.com Contact our support at https://hirschmann-support.belden.eu.com You can contact us in the EMEA region at ...