Hirschmann OS20–001000T5T5TAFUHB User Manual

Installation unmanaged ip54 switch octopus os20/os24 unmanaged
Hide thumbs Also See for OS20–001000T5T5TAFUHB:

Advertisement

Quick Links

User Manual

Installation
Unmanaged IP54 Switch
OCTOPUS OS20/OS24 Unmanaged
x y
P1 P2
OCTOPUS
OS20
1
6
Unmanaged
2
7
ETHERNET Switch
3
8
4
9
5
10
OS20-001000T5T5TAFUHB
Power
Power
5
3
2
4
1
Pin Function
1
P1+
2
N.C.
3
P-
4
P2+
5
N.C.
OS20–001000T5T5TAFUHB
x y
P1
P2
FAULT
OCTOPUS
OS24
1
6
Unmanaged
2
7
ETHERNET Switch
3
8
P
4
9
5
10
Port 2-5, 7-10
OS24-081000T5T5TFFUHB
Power
1
5
Power
2
4
3
Pin Function
1
P1+
2
3
N.C.
P-
4
5 P2+
OS24–081000T5T5TFFUHB
Installation OCTOPUS OS20/OS24 Unmanaged
Release 08 07/2015
x y
P
OCTOPUS
OS20
1
6
Unmanaged
2
7
ETHERNET Switch
3
8
4
9
5
10
OS20-001000T5T5TNEUHB
Power
Power
4
2
3
1
Pin Function
1
P+
2
N.C.
3
P-
4 N.C.
OS20–001000T5T5TNEUHB
x y
P
FAULT
OCTOPUS
OS24
1
6
Unmanaged
2
7
ETHERNET Switch
3
8
P
4
9
5
10
Port 2-5, 7-10
OS24-081000T5T5TNEUHB
Power
Power
4
2
3
1
Pin Function
1
P+
2
N.C.
3
P-
4 N.C.
OS24–081000T5T5TNEUHB
https://hirschmann-support.belden.eu.com
Technical support

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OS20–001000T5T5TAFUHB and is the answer not in the manual?

Questions and answers

Summary of Contents for Hirschmann OS20–001000T5T5TAFUHB

  • Page 1: User Manual

    Unmanaged Unmanaged ETHERNET Switch ETHERNET Switch Port 2-5, 7-10 Port 2-5, 7-10 OS24-081000T5T5TFFUHB OS24-081000T5T5TNEUHB Power Power Power Power Pin Function Pin Function N.C. N.C. 5 P2+ 4 N.C. OS24–081000T5T5TFFUHB OS24–081000T5T5TNEUHB Installation OCTOPUS OS20/OS24 Unmanaged Technical support Release 08 07/2015 https://hirschmann-support.belden.eu.com...
  • Page 2 In addition, we refer to the conditions of use specified in the license contract. You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com). Hirschmann Automation and Control GmbH Stuttgarter Str.
  • Page 3: Table Of Contents

    Contents Safety instructions About this Manual Legend Description General device description Device name and product code Device view Power supply 1.4.1 Supply voltage with the characteristic value A 1.4.2 Supply voltage with the characteristic value F 1.4.3 Supply voltage with the characteristic value N Ethernet ports 1.5.1 10/100 Mbit/s twisted pair port 1.5.2 10/100 Mbit/s PoE port...
  • Page 4 Connecting data cables Monitoring the ambient air temperature Maintenance and service Technical data Further Support Installation OCTOPUS OS20/OS24 Unmanaged Release 08 07/2015...
  • Page 5: Safety Instructions

    Certified usage   Use the product only for the application cases described in the Hirschmann product information, including this manual.  Operate the product only according to the technical specifications. See “Technical data” on page 31.  Connect to the product only components suitable for the requirements of the specific application case.
  • Page 6 Device casing  Only technicians authorized by the manufacturer are permitted to open the casing.  Never insert pointed objects (narrow screwdrivers, wires, etc.) into the device or into the connection terminals for electric conductors. Do not touch the connection terminals. ...
  • Page 7 Supply voltage  The supply voltage is electrically isolated from the housing.  Use undamaged parts.  Relevant for North America: Only use copper wire/conductors of class 1, 75 °C.  Applies to devices featuring supply voltage with the characteristic value F: Exclusively connect SELV circuits with the voltage restrictions in accordance with IEC/EN 60950-1 to the supply voltage connections.
  • Page 8 In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address: Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany Tel.: +49 1805 141538 The device can be used in the industrial sector.
  • Page 9 FCC note:  This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation. Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations.
  • Page 10: About This Manual

    About this Manual The “Installation” user manual contains a device description, safety instructions, a description of the display, and the other information that you need to install the device. Legend The symbols used in this manual have the following meanings: ...
  • Page 11: Description

     Autonegotiation  Autopolarity Mount the device on a level surface with four M5 screws. The Hirschmann network components help you ensure continuous communication across all levels of the company. Connect your devices to:  devices of the OCTOPUS family ...
  • Page 12: Device Name And Product Code

    Device name and product code The device name corresponds to the product code. The product code is made up of characteristics with defined positions. The characteristic values stand for specific product properties. You have numerous options of combining the device characteristics. You can determine the possible combinations using the configurator which is available in the Belden E-Catalog (www.e-catalog.beldensolutions.com) on the web page of the device.
  • Page 13  Railway (train)  Germanischer Lloyd  Software variant Unmanaged Configuration Hirschmann Device model IP54 Table 2: Device name and product code The following table informs you about the possible device variants. Device name and product code Order number Characteristics...
  • Page 14: Device View

    Device view P1 P2 OCTOPUS OS20 Unmanaged ETHERNET Switch OS20-001000T5T5TAFUHB Power Power Pin Function N.C. N.C. OS20-001000T5T5TAFUHB LED display elements Device Status Supply voltage 1 Supply voltage 2 100 Mbit/s ports Connecting the supply voltage Grounding screw Product code LED display elements port state Installation OCTOPUS OS20/OS24 Unmanaged Release 08 07/2015...
  • Page 15 OCTOPUS OS20 Unmanaged ETHERNET Switch OS20-001000T5T5TNEUHB Power Power Pin Function N.C. 4 N.C. OS20-001000T5T5TNeUHB LED display elements Device Status Supply voltage 100 Mbit/s ports Connecting the supply voltage Grounding screw Product code LED display elements port state Installation OCTOPUS OS20/OS24 Unmanaged Release 08 07/2015...
  • Page 16 FAULT OCTOPUS OS24 Unmanaged ETHERNET Switch Port 2-5, 7-10 OS24-081000T5T5TFFUHB Power Power Pin Function N.C. 5 P2+ OS24-081000T5T5TFFUHB LED display elements Device Status Supply voltage 1 Supply voltage 2 FAULT Total PoE output Ports 100 Mbit/s ports Ports 100 Mbit/s PoE+ ports 2,3,4,5,7,8,9,10 Connecting the supply voltage Grounding screw...
  • Page 17: Device Status

    FAULT OCTOPUS OS24 Unmanaged ETHERNET Switch Port 2-5, 7-10 OS24-081000T5T5TNEUHB Power Power Pin Function N.C. 4 N.C. OS24-081000T5T5TNEUHB LED display elements Device Status Supply voltage FAULT Total PoE output Ports 100 Mbit/s ports Ports 100 Mbit/s PoE+ ports 2,3,4,5,7,8,9,10 Connecting the supply voltage Grounding screw Product code LED display elements...
  • Page 18: Power Supply

    Power supply 1.4.1 Supply voltage with the characteristic value A A 5-pin M12 plug is available for the redundant supply to the device. See “Devices featuring supply voltage with the characteristic value A” on page 22. 1.4.2 Supply voltage with the characteristic value F A 5-pin 7/8"...
  • Page 19: 10/100 Mbit/S Poe Port

    Function Transmission path RD+ Receive path TD− Transmission path RD− Receive path Housing: shield Table 3: Pin assignment of 10/100 Mbit/s twisted pair port, M12 socket 1.5.2 10/100 Mbit/s PoE port Some device variants support Power over Ethernet based on IEEE 802.3at (PoE+) via a twisted pair: Device Number of TX ports...
  • Page 20: Pin Assignments

    1.5.3 Pin assignments M12 4-pin (D coded) Data Positive V Negative V TX− Positive V RX− Negative V M12 8-pin (X-coded) 10/100 Mbit/s 1000 Mbit/s BI_DB+ Negative V RX− BI_DB− Negative V BI_DA+ Positive V TX− BI_DA− Positive V — BI_DC+ —...
  • Page 21: Port State

    Port state  The green and yellow LEDs at the individual twisted pair ports provide port-related information. Display Color Activity Meaning 1 ... 10 Link status — None Device detects an invalid or missing link Green Lights up Device detects a valid link Yellow Flashing Device is transmitting and/or...
  • Page 22: Installation

    Installation The devices have been developed for practical application in a harsh industrial environment. On delivery, the device is ready for operation. Perform the following steps to install and configure the device:  Checking the package contents  Connecting the connector for the supply voltage ...
  • Page 23: Devices Featuring Supply Voltage With The Characteristic Value F

     Use a power supply cable which is suitable for the voltage, the current and the physical load. Hirschmann recommends a wire diameter of 0.5 mm² to 0.75 mm² (AWG20 to AWG18).  The supply voltage is connected via a 5-pin M12 connector (A coding, e.g.
  • Page 24: Devices Featuring Supply Voltage With The Characteristic Value N

     Use a power supply cable which is suitable for the voltage, the current and the physical load. Hirschmann recommends a wire diameter of 0.75 mm² to 1.0 mm² (AWG18 to AWG16).  The supply voltage is connected via a 5-pin 7/8" connector.
  • Page 25: Installing And Grounding The Device

    Figure Function + 72 ... 110 V DC N.C. N.C. Not used Not used P− Table 7: Pin assignment of the 4-pin 7/8" connector for connecting the supply voltage  Connect the power supply cables. Installing and grounding the device WARNING ELECTRIC SHOCK Applies to devices featuring supply voltage with the characteristic value N:...
  • Page 26: Grounding The Device

    To protect the exposed uninstalled contacts of the components from dirt, connect the individual system components in a dry and clean working area.  When you are selecting the installation location, make sure you observe the climatic threshold values specified in the technical data. Prevent heat from the surroundings from affecting the device.
  • Page 27: Connecting The Supply Voltage

     Insert the power supply cable through the ferrite 3 times.  Position the ferrite as close as possible to the voltage input (max. distance 19.7 inches (50 cm)).  Lock the ferrite. Note: To open the ferrite use the key supplied. Connecting the supply voltage ...
  • Page 28 Connecting data cables You have the ability to connect end devices or other segments to the ports of the device via twisted-pair cables. Note the following general recommendations for data cable connections in environments with high electrical interference levels:  Keep the length of the data cables as short as possible.
  • Page 29 Monitoring the ambient air temperature Operate the device below the specified maximum ambient air temperature exclusively. The ambient air temperature is the temperature of the air at a distance of 2 in (5 cm) from the device. It depends on the installation conditions of the device, e.g.
  • Page 30 Check regularly whether there is an updated version of the software that provides you with additional benefits. You find information and software downloads on the Hirschmann product pages on the Internet (www.hirschmann.com). Note: You will find information about the complaints and returns procedures on the Internet under http://www.beldensolutions.com/en/Service/Repairs/index.phtml...
  • Page 31: Technical Data

    Technical data General technical data  Dimensions See “Dimension drawings” on page 33. W × H × D Weight 67.02 oz (1900 g) Power supply Redundant power supply Type A Note: Ensure that the externally power unit connected upstream fulfills one of following conditions: ...
  • Page 32 Power supply Rated voltage range DC 72 V ... 110 V Type N Voltage range DC incl. maximum 50,4 V ... 138 V tolerances Connection type 7/8" connectors, 4-pin Power loss buffer > 10 ms No buffering of powered devices (PDs) Overload current protection at input Non-replaceable fuse Back-up fuse...
  • Page 33: Dimension Drawings

    Dimension drawings  183,8 mm 7.24 inch 171,8 mm 6.77 inch Figure 1: Dimensions EMC and immunity  EMC interference immunity IEC/EN 61000-4-2 Electrostatic discharge Contact discharge 6 kV Air discharge 8 kV IEC/EN 61000-4-3 Electromagnetic field 80 MHz ... 2700 MHz 20 V/m IEC/EN 61000-4-4 Fast transients (burst)
  • Page 34 EMC interference emission FCC 47 CFR Part 15 Class A German Lloyd Classification + Construction Guidelines VI-7-3 Part 1 Ed.2001 Stability Vibration IEC 60068-2-6 Test FC test level according to IEC 61131-2 Germanischer Lloyd Guidelines for the Performance of Type Tests Part 1 IEC 870-2-2 table 3 normal installation according to EN 61850-3...
  • Page 35: Scope Of Delivery

    Power consumption/power output  Device name and product Maximum power consumption Power output code OS20-001000T5T5TAFUHB 5.8 W 19.8 Btu (IT)/h OS20-001000T5T5TNEUHB 12 W 41 Btu (IT)/h OS24-081000T5T5TFFUHB 80 W 68 Btu (IT)/h OS24-081000T5T5TNEUHB 80 W 68 Btu (IT)/h Scope of delivery ...
  • Page 36 Accessories  Some products recommended as accessories do not support the entire temperature range specified for the device and can thus restrict the possible range of usage for the overall system. Unsealed accessory parts are not suitable for use within an IP54 area. ...
  • Page 37 If your device has a shipping approval according to Germanischer Lloyd, you find the approval mark printed on the device label. You will find out whether your device has other shipping approvals on the Hirschmann website under www.hirschmann.com in the product information.
  • Page 38: Further Support

    Further Support Technical Questions  For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You will find the addresses of our partners on the Internet at http://www.hirschmann.com Contact our support at https://hirschmann-support.belden.eu.com You can contact us in the EMEA region at ...
  • Page 39 Installation OCTOPUS OS20/OS24 Unmanaged Release 08 07/2015...

Table of Contents