Compact and modern furnace for dental practices and laboratories with space for bridges with up to 14 units (16 pages)
Summary of Contents for vita VITA Easyshade V
Page 1
VITA Easyshade ® Operating manual VITA Farbkommunikation VITA Farbkommunikation VITA shade determination VITA shade communication VITA shade reproduction VITA shade control Date of issue: 01.19...
Page 2
VITA Easyshade ® Purchase date: VITA Easyshade V serial number Handpiece / calibration block holder: VITA Easyshade V charging station serial number: Dealer:...
6.1.2 Display of shade differences 11.4 Glossary 6.1.3 Detailed information - 11.5 Patents and trademarks 11.6 Limited liability for subsequent defects VITA SYSTEM 3D-MASTER shade 6.1.4 VITA SYSTEM 3D-MASTER 11.7 Warranty interpolated shades 6.1.5 Detailed information - VITA classical A1–D4 shades 6.1.6 Display of the VITABLOCS shade...
3D-MASTER shades, including the BLEACHED SHADE GUIDE shades, as well as the VITA classical A1–D4 shades. You also have access to digital tooth shade determination and documentation with the aid of the VITA mobileAssist app or the VITA Assist PC software. To achieve precise shade determinations, please read this manual all the way through before using the instrument.
VITA Zahnfabrik provides no warranty in this case. 2. Never look directly into the measuring tip of the VITA Easyshade V while the light source is switched on. 3. Do not immerse the VITA Easyshade V handpiece or the base station in water or other liquids.
Page 6
VITA Zahnfabrik to provide support or other services in connection therewith. Any right or license to use any software data, information or other intellectual property rights of VITA Zahnfabrik, or any obligation to provide support, must be conveyed by separate written agreement with VITA Zahnfabrik.
American Dental Association (ADA). The software VITA Assist with the VITA ShadeAssist module (included in the scope of delivery or by download at http://www.vita-zahnfabrik.com/vita-assist) for the transmission and documentation of the measured natural tooth...
Sales and shipping packaging DEASY5VP Check the delivery for completeness and any transport damage. Note: In the unlikely case that the contents of the package are incomplete or damaged, please contact the VITA Zahnfabrik Service Hotline immediately. Tel. No.: +49 (0)7761 562 222...
VITA Easyshade – Scope of delivery ® 3.2 Replacement parts and accessories for users The following replacement parts and accessories can be obtained from VITA: Article Piece count VITA article number Protective caps (9x18 pcs.) D58000S Sales and shipping packaging...
Scroll left time interpolated shades interpolated shades or back Scroll Save Training mode Training mode Regulating right VITA classical A1–D4 VITA SYSTEM 3D-MASTER volume Bluetooth connection Bluetooth connection Send data Send data Android Android Base shade Averaged shade Shade determination...
Important: Check to make sure that the handpiece and the calibration block in the charging station have the same serial number; if this is not the case, please contact VITA immediately. 5.2 Battery charge status You can find the current battery status in the information directory in the main menu.
Before using on the patient, the instrument needs to be cleaned and disinfected properly. Information on cleaning and disinfecting the VITA Easyshade V can be found in section 10. Use a new VITA Easyshade V protective cap for each patient.
Note: The VITA Easyshade V is calibrated to the supplied calibration block at delivery and may only be used with this calibration block. If you have more than one VITA Easyshade V, you should ensure that the charging stations are not confused, in order to guarantee the precision of...
Page 14
VITA Easyshade – First use ® Recommendation: Use protective caps for application on a patient. If they are used, a new white balance must always be initiated after the cap is attached and before the tooth shade determination on the patient.
Function: "Automatic triggering of the measurement." Note: You can press the measurement button before placing the measuring tip on the tooth. The VITA Easyshade V does not trigger the measurement until the instrument is placed on the tooth. VITA Easyshade V displays the results of the measurement.
Page 16
Note: Before the shade of a tooth is determined, you should place a pro- tective cap on the measuring tip of the VITA Easyshade V and conduct a white balance. Before a measurement procedure, it is recommended that you completely remove specks from the tooth surface.
VITA Easyshade – First use ® 5.7 Basic settings As soon as you have started up the instrument, you can choose the basic settings. Use the arrows to go to the basic settings on the third page of the main menu.
VITA Easyshade – First use ® Touch the top button, which displays date and time. Use the arrows to scroll to the right or left in order to set the date and time. Use the middle button to regulate volume.
Page 19
Bluetooth is activated, but not yet paired with a device. If the VITA Easyshade V is paired with a Windows PC or an Android device, radio waves are displayed in the upper right corner next to the Bluetooth icon.
6.1.2 Display of shade differences Using a traffic light function, the VITA Easyshade V shows you how close the measured tooth shade is to the next VITA SYSTEM 3D-MASTER or VITA classical A1–D4 shade. The degree of the match is indicated by a green, yellow or red bar.
Yellow bar means "average:" the measured tooth shade has a noticeable, but still acceptable difference from the specified VITA SYSTEM 3D-MASTER or VITA classical A1–D4 shade. In the anterior area, however, this result may not be acceptable. Red bar means "adjust." The measured tooth shade has a clearly noticeable difference from the specified VITA SYSTEM 3D-MASTER or VITA classical A1–D4 shade.
4R2.5 The 29 VITA SYSTEM 3D-MASTER shades can be found in bold print in the tables above. The tables also show the 52 interpolated shades that can be obtained with an equal mixture of the respective VITA SYSTEM 3D-MASTER materials.
Page 23
L (Delta L, lightness): Deviation of lightness of the measured tooth from the displayed VITA classical A1–D4 shade. The measured tooth is lighter (+) or darker (-) than the VITA classical A1–D4 shade. C (Delta C, chroma): Deviation of chroma of the measured tooth from the displayed VITA classical A1–D4 shade.
6.1.6 Display of the VITABLOCS shade The VITABLOCS display provides you with an indication of which VITA CAD / CAM material should be used for a highly accurate reproduction of the shade of the measured tooth. To do this, please select the VITABLOCS symbol in the top bar.
To display the bleached shade, please select the sun symbol in the top bar. When selecting this display mode, the bleached index is set according to the VITA Bleachedguide 3D-MASTER (VITA Product Number B361) for the measured shade. The bleached index enables a simple check of tooth whitening.
With averaged shade determination, up to 30 measurements can be performed on a natural tooth. The determined tooth shade is displayed in the VITA SYSTEM 3D-MASTER and VITA classical A1–D4 tooth shade systems. It is recommended that at least four measurements are taken.
Measurement result After successfully measuring all areas, the shades are displayed in the VITA SYSTEM 3D-MASTER and VITA classical A1–D4 tooth shade systems. If an error occurs during the measurement, the instrument produces a long signal tone, and an "X" is displayed in the corresponding tooth area.
Page 28
To obtain extended shade information, please touch one of the displayed shade results. Note: The measurement data from VITA Easyshade V depends on the measurement mode and is only valid for natural teeth. Shade samples can only be measured in the training mode. Measurements on dental restorations should always be performed in the mode "Verifying the...
(user standard) You can also activate the VITA SYSTEM 3D-MASTER interpolated shades. VITA Easyshade V enables dental specialists to check how well the shade of the ceramic restoration matches an indicated shade. This enables you to check the 29 VITA SYSTEM 3D-MASTER shades, the 52 VITA SYSTEM 3D-MASTER interpolated shades, as well as the 16 VITA classical A1–D4 shades.
Page 30
To select a target shade, please choose the first number or letter by touch. After this selection, only numbers and letters can still be selected, which can produce a corresponding VITA SYSTEM 3D-MASTER or VITA classical A1– D4 shade. To select interpolated shades, please switch over to the extended mode by using the button.
Page 31
VITA Easyshade – Operating modes ® RED means "Adjust." This means that there is a recognizable difference between the base shade of the restoration and the target shade it was compared to. The restoration must be reworked to achieve an acceptable shade match.
Touch the Save symbol. The measured shade is now saved and displayed as an approximate VITA classical A1–D4 and VITA SYSTEM 3D-MASTER shade. All shade deviations are set to zero after saving, and the bar is green. This shade is now defined as a user standard.
The measurement is performed without further interaction as soon as the instrument is stable on the surface. After completing a measure- ment, the VITA Easyshade V produces an acoustic signal, and the shade of the crown is displayed in the VITA classical A1–D4 and VITA SYSTEM 3D-MASTER tooth shade systems.
® 7 Training mode With this function, you can practice the use of the instrument on a VITA shade guide. You reach training mode via the Settings menu item. You can use the arrows to scroll to the second page.
Page 35
(below the neck of the tooth) of the shade tab. Now press the measurement button. The closest tooth shade is displayed. Note: In Training Mode, the 29 shades of the VITA SYSTEM 3D-MASTER and the 16 VITA classical A1–D4 shades are displayed.
If the measurement memory already contains measurements, it is possible to navigate within the recorded data by touching the Arrow symbol. After selecting the VITA classical A1–D4 or VITA SYSTEM 3D-MASTER shade specification, you will return to the detail display (Fig. shows details of the...
VITA Easyshade – Measurement memory ® 8.2 Deleting measurements Single deletions To delete single measurements from the measurement memory, please select the corresponding measurement in the measurement memory and touch the Info symbol. Then touch the Recycle Bin symbol. Deleting all records To delete all saved measurements, please select the Recycle Bin symbol in the main menu and delete all measurements permanently.
VITA Easyshade V will be visible for two minutes. If the pad- lock (icon) is locked, you can touch it to make VITA Easyshade V visible again. Go to the "Assist" tab in the VITA Assist Software and select "Options." Go to "Easyshade"...
Restoration mode results cannot be transmitted. The VITA Easyshade V must be connected to the computer to transmit data to Windows and Android devices. An existing connection is displayed as a wave in the measuring mode symbol.
VITA Easyshade V will be visible for two minutes. If the pad- lock (icon) is locked, you can touch it to make VITA Easyshade V visible again. Go to Settings Bluetooth on your iOS device. Make sure Bluetooth is enabled.
To reconnect VITA Easyshade V with a previously used device, pairing must be carried out again. To do this, remove VITA Easyshade V from the list of known devices in the Bluetooth menu in your iOS device. Use the icon ("Ignore this device") and then re-connect VITA Easyshade V.
VITA Easyshade – Appendix ® 11 Appendix 11.1 Error message Error No. Symbol Meaning No measurement object was recognized. Please repeat the measurement procedure. The shade is outside of the measurement range. Please perform a white balance. The Bluetooth data transmission is defective.
Page 43
VITA Easyshade – Appendix ® Error No. Symbol Meaning Device temperature too low during measurement (< 16°C). Permissible operating temperature: min. 16°C, max. 45°C. Device temperature too high during measurement (> 45°C). Permissible operating temperature: min. 16°C, max. 45°C. Measurement uncertain. The measurement result is valid, but should be repeated if necessary.
Place the measuring tip again as requested. After switching on, no With the VITA Easyshade V, a white balance must first be performed measurement with VITA Easyshade V after the device is switched on. Only after this task is completed, is possible.
VITA Easyshade – Appendix ® 11.3 Technical data Length / Width / Height: 20.5 cm / 8.5 cm / 10.5 cm Weight: Ca. 420 g (without power cable) Battery: 2 pcs. Ni-MH 1.2V 1.900mAh Electrical connection: 100V-240V, 50-60Hz Power consumption max. 5W...
VITA SYSTEM 3D-MASTER shades Refers to the 29 shade sample teeth, including three bleached shade samples of the lightness group 0 and the 52 interpolated shades of the VITA SYSTEM 3D-MASTER. VITA classical A1–D4 shades Refers to the 16 original VITA classical A1–D4 shades of the VITA classical A1–D4 shade guide.
Other trademarks mentioned in this document are the property of the respective company. 11.6 Limited liability for subsequent defects VITA does not accept any liability for data loss caused by the use of the VITA Assist DVD. 11.7 Warranty The warranty claims of the first buyer of the VITA Easyshade V spectrophoto- ®...
Page 48
The VITA Modulbox is not necessarily a component of the product. Date of issue of this information: 01.19 After the publication of this information for use any previous versions become obsolete.
Need help?
Do you have a question about the VITA Easyshade V and is the answer not in the manual?
Questions and answers