Danfoss PVG 100 Service And Parts Manual page 11

Proportional valves
Hide thumbs Also See for PVG 100:
Table of Contents

Advertisement

Service and Parts Manual
Installation
Installation and technical
data for PVPE (solenoid
relief valve)
PVPE connection
PVG 100 Proportional Valves
1
(coil nut)
Position
1
2
Max. operation pressure
Max. coil surface temperature
Rated voltage
Current consumtion
Power consumtion
Max. permissible deviation from rated supply voltage
When installing the wire remember to
connect the built-in diode to the plug
pins.
520L0888 • Rev BB • Feb 2015
2.5 mm
2 Nm
[17.5 lbf•in]
2
(cartridge valve)
Across flats
22 mm
[0.87 in]
36 mm
[1.42 in]
22°C (71,6°F) coil temperature
110°C (230°F) coil temperature
22°C (71,6°F) coil temperature
110°C (230°F) coil temperature
Max. tightening torque
5 Nm
[45 lbf·in]
85 Nm
[750 lbf·in]
350 bar [5076 bar]
155°C [311°F]
12 V –– __
24 V –– __
1.55 A
0.78 A
1.00 A
0.50 A
19 W
19 W
12 W
12 W
±10%
P106 288E