30
C
2
HAPTER
Maintenance
Green LED
Figure 35. Electronic module
On the bottom left of the packer module, a
green LED flashes on and off (Figure 36.
"Status LED").
Figure 36. Status LED
6.
Press and hold the button on the settings
switch (see Figure 37. "Multi-cycle settings
switch") for about three to four seconds. A
continuous red light will appear.
Settings switch
Figure 37. Multi-cycle settings switch
7.
At this time, press the button the number of
times you want the packer to continuously
cycle.
Flashing green LED
Note:The module has been set at the factory
to three cycles.
Once you have entered the desired
number of cycles, the LED flashes red/
green the same number of times to confirm
that the new settings have been stored.
8.
On the control station or the right-hand side
console, press the green
to test the new settings of the packer
multi-cycle function.
Emergency
Stop Button
Figure 38. Right-hand side control station
9.
If the packer performs the desired number
of cycles, re-install the side panel. The
vehicle is ready to use the new settings.
Note:For any other issues concerning the
multi-cycle function, please contact
LabriePlus.