Waste Water Drainage - Frima VarioCooking Center 112T Original Installation Instructions

Table of Contents

Advertisement

Waste water drainage

DN40
1
Ø 40mm
Ø
1 9/16"
2
Ø 40mm
Ø
1 9/16"
3
v03
Warning!
• Only use a rigid pipe, resistant to steam tempe-
Min. 3%
• The temperature of waste water is lower than
Requirements
• It is forbidden to weld a drainage pipe to the
• To avoid odour reflux, the drainage pipe should
VCC 112T
• The drainage pipe should be the same diame-
• The drainage pipe should have a constant slope
Position
VCC112T
VCC112L
VCC 112L
Verifications
After installation of the outlet, fill the tanks with 6
litres of hot water each and carry out a test:
» By activating each tank separately.
» Both tanks at the same time.
The water should drain without air bubbles
appearing.
If this is not the case, re-install the outlet or ventilate
the pipes. Example Fig. 3. It is recommended to
carry out the ventilation as close as possible to the
U-bend, for easy elimination of air trapped between
the U-bend and the appliance.
- 28 -
Burn hazard !
»
Be careful not to burn yourself,
cooking water may be hot when drai-
ned!
rature. (PP Type)
100 °C
outlet of the appliance.
have a U-bend. Our appliance does not have
one.
ter as that of the appliance, it is not accep-
table to insert a pipe with a smaller diameter.
of at least 3 %.
Fig.1
Fig.2