Frima VarioCooking Center 112T Original Installation Instructions page 26

Table of Contents

Advertisement

Electrical connection:
Connection values
VCCM 112T
3 AC 200V
3 AC 220V
3 NAC 400V
3 NAC 400V Dynamic
3 NAC 415V
3 NAC 415V Dynamic
VCCM 112L
3 AC 200V
3 AC 220V
3 NAC 400V
3 NAC 400V Dynamic
3 NAC 415V
3 NAC 415V Dynamic
Regarding the cable cross-section:
The current consumption, protection and cross sec-
tion of supply cables depends on:
• Local regulations
• The quality and length of the cable
• The network quality.
They should therefore be adapted to local conditions.
The values indicated are for a cable length of 2m
maximum. It is therefore your responsibility to adapt
these values according to the cable length which you
will use.
Regarding the supply voltage
The permitted tolerance for the supply voltage (input
voltage, see data plate) is between -10 % and
+10 %.
50/60Hz: Our appliances are compatible with both
frequencies without the need for technical modifi-
cations.
v03
Power
Curent con~
(kW)
sumption (A)
17
49
15
39
17
23
13
19
18
25
14
19
28
79
25
66
28
40
21
30
30
42
23
31
Standardised
protection (A)
50
40
25
20
25
20
80
80
40
32
50
32
It is strongly recommended not to use a
rigid cable for connection with our appliance.
Maximum size of supply cables
Maximum diameter
(Feeding through the cable glands)
VCCM 112T
VCCM 112L
Maximum cross-section
(Connection to the supply terminal)
VCCM 112T
VCCM 112L
Demonstration mode power
Demo mode* "Reduced"
Demo
mode*
"On" (full)
* Demo mode, see chapter "Installation Options"
paragraph "demonstration mode".
- 26 -
Min. recommended
cross-section (mm
10
6
2.5
2.5
2.5
2.5
16
16
6
4
10
4
Ø Max. 25 mm (1")
Ø Max. 32 mm (1 17/64")
Max. 10 mm
(0 1/64 in²)
2
Max. 16 mm
(0 5/8 in²)
2
230 W
115 W
2 )