Remove 3" (76.2mm) of cable jacket and untwist pairs.
3
Cut conductors on an angle and insert into cap.
5
Trim conductors flush with cap using wire snipping tool (CWST).
NOTE: Cable jacket is inside the cover.
7A
Apply pressure to cap until it clicks again. Cap must be flush on
housing.
1
Push forward and down against latch at end of guide ramp until cap releases.
--- FOR USE IN KEYSTONE STYLE OUTLETS AND PATCH PANELS ONLY ---
--- OVER FOR KEYSTONE STYLE PANEL OPENING REQUIREMENTS ---
** Denotes jack module color code.
For Technical Support: www.panduit.com/resources/install_maintain.asp
NetKey Keystone Style Jack Modules
Part Numbers: NK366M**Y, NK388M**Y, NK588M**Y, NK5E88M**Y, NK5E88M**Y-Q
INSTALLATION INSTRUCTIONS
Termination Cap Removal Instructions
Page 1 of 2
2
Straighten conductors and arrange in proper color sequence.
4
Pull conductors until outer jacket is inside cap. Bend up 90°.
6
Snap cap squarely on housing until it clicks.
7B
Use Snap Tool (7A) or standard Slip Lock Pliers (7B).
2
Slide screwdriver under cap to separate from housing.
NK178D