Access power system.
4 amp @ 12vdc or 3a/24vdc
eight (8) fused outputs.
4 amp @ 12vdc or 3a/24vdc
eight (8) class ii power limited outputs.
6 amp @ 12vdc or 24vdc
eight (8) fused outputs.
6 amp @ 12vdc or 24vdc
eight (8) class ii power limited outputs
Summary of Contents for LifeSafety Power FlexPower Vantage R8 series
Page 1
Eight (8) Fused outputs Eight (8) Class II Power Limited outputs For 230VAC input add "/E" to model number - example FPV6-R8E1/E For larger enclosure change E1 suffix to E2 in model number - example FPV6-R8E2 LifeSafety Power, Inc. PH 888.577.2898 TechSupport@LifeSafetyPower.com P03-054...
Page 2
FlexPower Vantage R8 Access Power System - Installation Manual Symbol Definitions Batteries (if used) should be maintained at an ambient tem- The following symbols are used throughout this manual: perature of between 32 and 120 degrees Fahrenheit (0-49 Celsius) or premature loss of battery power could occur. This symbol is intended to alert the installer of shock hazards within the enclosure.
Page 3
FlexPower Vantage R8 Access Power System - Installation Manua FPV4 Power Supply Overview - Read before Power Up This guide gives the basic information needed to install a system containing a single Vantage Power Supply for most applications. AC Voltage Select Jumper - - ...
Page 4
FlexPower Vantage R8 Access Power System - Installation Manual FPV6, 102, 104 Power Supply Overview - Read before Power Up This guide gives the basic information needed to install a system containing a single Vantage Power Supply for most applications. FPV4 FPV6 12/24V @ 6A...
Page 6
FlexPower Vantage R8 Access Power System - Installation Manual R8 Power Control Accessory Overview - continued in or external to the device. NOTE When a dry contact output is needed, the Yellow and Black jumpers must be removed and the output di- odes must be cut.
FlexPower Vantage R8 Access Power System - Installation Manua R8 Power Control Accessory Input and Output Wiring INPUT WIRING Each input on the R8 / R8P has an “IN” terminal and a “GND” INPUT 1 - 4 INPUT 5 - 8 terminal.
Page 8
FlexPower Vantage R8 Access Power System - Installation Manual R8 Power Control Dry Contact Output The outputs of the R8/R8P have built-in reverse protection di- odes. If a delay in lock release is present or if the zone is being used as a dry contact output, the diode from that zone may be removed from the circuit as shown below.
FlexPower Vantage R8 Access Power System - Installation Manua Vantage Power Supply/Charger FAI Input Usage This section provides more detailed information on the connection and usage of the FAI Input located on the main power supply board. Activation with a Normally Open Relay Contact Latching the FAI Input FAI Activates when the Latching of the FAI Input...
Page 10
FlexPower Vantage R8 Access Power System - Installation Manual Tamper Switch Wiring Vantage power supply systems with an enclosure may in- FPV Power Supply clude a normally closed tamper switch for monitoring by the host panel. SYS FAULT AC FAULT C NC NO The tamper switch can either be brought into a dedicated input in the panel (see the panel's instructions), or the...
Page 11
FlexPower Vantage R8 Access Power System - Installation Manua FPV4-R8E1 / FPV6-R8E1 Electrical / Mechanical Specifications FPV4-R8E1 FPV6-R8E1 AC Input Voltage 120VAC or 230VAC at 50-60Hz 120VAC or 230VAC at 50-60Hz Current 1.8A maximum 3.7A maximum Standby Current 80mA 150mA DC Output at 12V Setting Voltage 11.3 - 12.0V...
Page 12
FlexPower Vantage R8 Access Power System - Installation Manual FPV102-R8E1 / FPV104-R8E1 Electrical / Mechanical Specifications FPV102-R8E1 FPV104-R8E1 AC Input Voltage 120VAC or 230VAC at 50-60Hz 120VAC or 230VAC at 50-60Hz Current 5.7A Standby Current 110mA 160mA DC Output Voltage 11.3 - 12.0V 23.4 - 25.0V (Auxiliary power-limited...
Page 13
4. Do not connect equipment to an AC power source that is controlled by a switch. 5. The power supplies shall be mounted in a Listed LifeSafety Power enclosure. 6. Trouble contacts shall be monitored by a listed alarm system.
Page 14
Conditions of Sale for this product, and in no case will LifeSafety Power or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice.