• TROUBLE SHOOTING
Symptom
Display Commander (DC)
will not turn ON
No power to the Body
Control Module (BCM)
DC screen flashing on and
off after installation
Light Group is not working.
Motor functions are not working Check 12V+ at pin 35.
Travel Lock is on
Functions not operating from
DC or App and App shows 0V
If an issue is unable to be resolved using the above methods, contact ASA Electronics Technical
Support at 1-877-845-8750 or email them at info@asaelectronics.com
Verify the BCM is powered on.
Check main fuse in Distribution Panel.
Check 12V+ on wire to DC (RED wire).
Check Ground wire to DC.
Check if the Red power LED is off,
Check the fuse in the Distribution Panel.
Check 12V+ on wire at pin 36. Check Ground wire at pin 34.
Cycle power to the BCM and DC.
Ensure the wires to the BCM and DC are connected and there is 12V.
Ensure the wires to the BCM and DC are not damaged or pinched.
Ensure the Battery is charged.
Cycle power to the BCM and DC.
Ensure wires are making contact with pins and 12V+ is present.
Check 12V+ at Pin 16.
Check fuse in the Distribution Panel.
Ensure 12V+ is removed from Pin 15.
Check to ensure RX & TX wires connected properly.
Solution