Jog - Siemens MICROMASTER 440 Operating Instructions Manual

0,12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

6 Commissioning
6.4.10

JOG

JOG frequency right
P1058 = ...
Frequency in Hz when the motor is
rotating clockwise in the jog mode.
JOG frequency left
P1059 = ...
Frequency in Hz when the motor is
rotating counter-clockwise in the jog
mode.
P1060 = ...
JOG ramp-up time
Ramp-up time in s from 0 to the
maximum frequency (p1082). JOG ramp-
up is limited by p1058 or p1059.
JOG ramp-down time
P1061 = ...
Ramp-down time in s from the maximum
frequency (p1082) to 0.
DIN
BOP
USS
BOP link
USS
COM link
CB
COM link
42
5.00 Hz
5.00 Hz
10.00 s
10.00 s
"1"
Tippen rechts
P1055
"0"
(0)
"1"
Tippen links
P1056
"0"
(0)
f
P1082
P1058
P1059
-P1082
JOG
f
p1082
(f
)
max
p1058
p1060
A0923
Operating Instructions (Compact)
Issue 10/06
t
p1061
A0923
t
t
t
MICROMASTER 440

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Micromaster 440 series

Table of Contents