Siemens MICROMASTER 440 Operating Instructions Manual page 12

0,12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

2 Electrical Installation
Input voltage range
Order No.
6SE6440- 2UE17-
Frame Size
Output Rating(CT)
Output Power
CT-Input Current 1)
CT-Output Current
VT-Input Current 1)
VT-Output Current
Fuse
Recommended
For UL specified
Input Cable, min.
Input Cable, max.
Output Cable, min.
Output Cable, max.
Weight
Tightening torques for
power terminals
Order No.
6SE6440- 2UE31-
Frame Size
Output Rating(CT)
Output Power
CT-Input Current 1)
CT-Output Current
VT-Input Current 1)
VT-Output Current
Fuse
Recommended
For UL specified
Input Cable, min.
Input Cable, max.
Output Cable, min.
Output Cable, max.
Weight
Tightening torques for
power terminals
1) Secondary conditions:
*
UL listed fuses such as Class NON from Bussmann are required for use in America
12
3 AC 500 V – 600 V, ± 10 %
2UE21-
5CA1
5CA1
0,75
1,5
[kW]
1,0
2,0
[hp]
1,3
2,6
[kVA]
2,0
3,7
[A]
1,4
2,7
[A]
3,2
4,4
[A]
2,7
3,9
[A]
10
10
[A]
3803-6
3803-6
3NA
*
*
3NE
2
1,0
1,0
[mm
]
18
18
[AWG]
2
10,0
10,0
[mm
]
8
8
[AWG]
2
1,0
1,0
[mm
]
18
18
[AWG]
2
10,0
10,0
[mm
]
8
8
[AWG]
5,5
5,5
[kg]
12,1
12,1
[lbs]
[Nm]
[lbf.in]
2UE32-
8DA1
2DA1
D
18,5
22,0
[kW]
25,0
30,0
[hp]
25,7
30,5
[kVA]
30,0
35,0
[A]
27,0
32,0
[A]
35,0
48,0
[A]
32,0
41,0
[A]
50
63
[A]
3NA
3820-6
3822-6
1817-0
1818-0
3NE
2
10,0
10,0
[mm
]
8
8
[AWG]
2
35,0
35,0
[mm
]
2
2
[AWG]
2
6,0
10,0
[mm
]
10
8
[AWG]
2
35,0
35,0
[mm
]
2
2
[AWG]
16,0
16,0
[kg]
35,0
35,0
[lbs]
[Nm]
[lbf.in]
Input current at the rated operating point - applies for the short-circuit voltage of the line
supply V
= 2 % referred to the rated drive converter power and a rated line supply voltage
k
of 500 V without line commutating reactor.
2UE22-
2UE24-
2UE25-
2CA1
0CA1
5CA1
C
2,2
4,0
5,5
3,0
5,0
7,5
3,7
5,8
8,6
5,3
8,1
11,1
3,9
6,1
9,0
6,9
9,4
12,6
6,1
9,0
11,0
10
16
16
3803-6
3805-6
3805-6
*
*
*
1,0
1,5
1,5
18
16
16
10,0
10,0
10,0
8
8
8
1,0
1,0
1,0
18
18
18
10,0
10,0
10,0
8
8
8
5,5
5,5
5,5
12,1
12,1
12,1
2,25
(20)
2UE33-
2UE33-
2UE34-
0EA1
7EA1
5FA1
E
30,0
37,0
45,0
40,0
50,0
60,0
39,1
49,5
59,1
48,0
58,0
69,0
41,0
52,0
62,0
58,0
69,0
83,0
52,0
62,0
77,0
80
80
125
3824-6
3824-6
3132-6
1820-0
1820-0
1022-0
16,0
25,0
25,0
6
3
3
35,0
35,0
150,0
2
2
300
16,0
16,0
25,0
6
6
3
35,0
35,0
150,0
2
2
300
20,0
20,0
56,0
44,0
44,0
123,0
10
(89)
Issue 10/06
(Unfiltered)
2UE27-
2UE31-
2UE31-
5CA1
1CA1
5DA1
D
7,5
11,0
15,0
10,0
15,0
20,0
10,5
16,2
21,0
14,4
21,5
24,9
11,0
17,0
22,0
18,1
24,9
30,0
17,0
22,0
27,0
25
32
35
3810-6
3812-6
3814-6
*
*
1803-0
2,5
4,0
6,0
14
12
10
10,0
10,0
35,0
8
8
2,5
4,0
4,0
14
12
12
10,0
10,0
35,0
8
8
5,5
5,5
16,0
12,1
12,1
35,0
10
(89)
2UE35-
2UE37-
5FA1
5FA1
F
55,0
75,0
75,0
100,0
73,4
94,3
83,0
113,0
77,0
99,0
113,0
138,0
99,0
125,0
160
160
3136-6
3136-6
1224-0
1224-0
50,0
50,0
1/0
1/0
150,0
150,0
300
300
35,0
50,0
2
1/0
150,0
150,0
300
300
56,0
56,0
123,0
123,0
50
(445)
MICROMASTER 440
Operating Instructions (Compact)
2
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Micromaster 440 series

Table of Contents