Siemens MICROMASTER 440 Operating Instructions Manual page 57

0,12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Issue 10/06
BI: Fct digital output 1
P0731=52.C
Defines the source for digital output 1.
NOTE
The brake relay can also be controlled
from another digital output (if this is
available) or using a distributed I/O
module. Analog to DOUT 1, it should
be guaranteed that the I/Os are
controlled by the status bit "MHB
active".
P0748 = 0
Inverting digital
outputs
This parameter allows the signals
to be output to be inverted.
DOUT channel
Function
xxxx.y
Holding brake release delay (entered in s)
P1216 = ...
Defines the time interval during which the frequency inverter runs with the min. frequency
p1080 after magnetizing, before the ramp-up starts.
P1216 ≥ brake opening time + relay opening time
Holding time after ramp-down (entered in s)
P1217 = ...
Defines time for which inverter runs at minimum frequency (p1080) after ramping down.
P1217 ≥ brake closing time + relay closing time
MICROMASTER 440
Operating Instructions (Compact)
52.3
Frequent settings:
52.0 Ready to power-up
52.1 Ready
52.2 Drive operational
52.3 Fault present
52.4 OFF2 active (present)
52.5 OFF3 active (present)
52.6 Power-on inhibit active (present)
52.7 Alarm active (present)
52.8 Deviation, setpoint/actual value
52.9 PZD / PLC control
0
52.A Maximum frequency reached
52.B Alarm: Motor current limit
52.C Motor holding brake active
52.D Motor overload
52.E Motor dir. of rotation, clockwise
52.F Frequency inverter overload
53.0 DC brake active
53.1 Actual freq. f_act > P2167 (f_off)
:
:
Invert DOUTs
0 ... 7
P0748 (0)
BI: Fct. of DOUT 1
P0731.C
rxxxx.y
(52:3)
P0731 = xxxx.y
Relay :
Text
- max. opening / closing time
CO/BO: State DOUTs
r0747
r0747
.0
0
-1
1
DC 30 V / 5 A
AC 250 V / 2 A
5 / 10 ms
6 Commissioning
0
Closed
0
Closed
0
Closed
0
Closed
1
Closed
1
Closed
0
Closed
0
Closed
1
Closed
0
Closed
0
Closed
1
Closed
0
Closed
1
Closed
0
Closed
1
Closed
0
Closed
0
Closed
int. 24 V
max. 100 mA
Kl.9
COM
Kl.20
NO
Kl.19
or
NC
Kl.18
Kl.28
1.0 s
1.0 s
57