Siemens MICROMASTER 440 Operating Instructions Manual page 8

0,12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

2 Electrical Installation
Input voltage range
Order No.
6SE6440- 2UC11
Frame Size
[kW]
Output Rating(CT)
[hp]
Output Power
[kVA]
CT-Input Current 1)
[A]
CT-Output Current
[A]
Fuse
[A]
Recommended
3NA
For UL specified
[mm
Input Cable, min.
[AWG]
[mm
Input Cable, max.
[AWG]
[mm
Output Cable, min.
[AWG]
[mm
Output Cable, max.
[AWG]
[kg]
Weight
[lbs]
[Nm]
Tightening torques
[lbf.in]
for power terminals
Order No.
6SE6440- 2UC24-
Frame Size
[kW]
Output Rating(CT)
[hp]
Output Power
[kVA]
CT-Input Current 1)
[A]
CT-Output Current
[A]
VT-Input Current 1)
[A]
VT-Output Current
[A]
Fuse
[A]
Recommended
3NA
3NE
For UL specified
[mm
Input Cable, min.
[AWG]
[mm
Input Cable, max.
[AWG]
[mm
Output Cable, min.
[AWG]
[mm
Output Cable, max
[AWG]
[kg]
Weight
[lbs]
[Nm]
Tightening torques
[lbf.in]
for power terminals
1) Secondary conditions:
*
UL listed fuses such as Class NON from Bussmann are required for use in America
8
3 AC 200 V – 240 V. ± 10 %
2UC12
-2AA1
-5AA1
A
0,12
0,25
0,16
0,33
0,4
0,7
1,1
1,9
0,9
1,7
10
10
3803
3803
*
*
2
1,0
1,0
]
18
18
2
2,5
2,5
]
14
14
2
1,0
1,0
]
18
18
2
2,5
2,5
]
14
14
1,3
1,3
2,9
2,9
1,1
(10)
2UC25-
2UC27-
0CA1
5CA1
5DA1
C
4,0
5,5
5,0
7,5
10,0
7,7
9,6
12,3
19,7
26,5
34,2
17,5
22,0
28,0
28,3
34,2
38,0
22,0
28,0
42,0
32
35
3812
3814
3820
*
*
1817-0 1820-0 1820-0 1021-0 1022-0 1225-0 1225-0 1227-0
2
4,0
4,0
10,0
]
12
12
2
10,0
10,0
35,0
]
8
8
2
4,0
4,0
10,0
]
12
12
2
10,0
10,0
35,0
]
8
8
5,5
5,5
17,0
12,1
12,1
37,0
2,25
(20)
Input current at the rated operating point - applies for the short-circuit voltage of the line
supply V
= 2 % referred to the rated drive converter power and a rated line supply voltage
k
of 240 V without line commutating reactor.
2UC13
2UC15
2UC17
-7AA1
-5AA1
-5AA1
B
0,37
0,55
0,75
0,5
0,75
1,0
1,0
1,3
1,7
2,7
3,6
4,7
2,3
3,0
3,9
10
16
16
3803
3805
3805
*
*
*
1,0
1,5
1,5
18
16
16
2,5
2,5
2,5
14
14
14
1,0
1,0
1,0
18
18
18
2,5
2,5
2,5
14
14
14
1,3
1,3
1,3
2,9
2,9
2,9
1,5
(13,3)
2UC31-
2UC31-
2UC31-
1DA1
5DA1
8EA1
D
7,5
11,0
15,0
18,5
15,0
20,0
25,0
18,4
23,7
29,8
38,0
50,0
62,0
42,0
54,0
68,0
50,0
62,0
71,0
54,0
68,0
80,0
50
80
80
100
3824
3824
3830
16,0
16,0
25,0
8
6
6
3
35,0
35,0
35,0
2
2
2
2
16,0
16,0
25,0
8
6
6
3
35,0
35,0
35,0
2
2
2
2
16,0
16,0
20,0
35,0
35,0
44,0
10
(89)
Issue 10/06
(Unfiltered)
2UC21
2UC21
2UC22
-1BA1
-5BA1
-2BA1
C
1,1
1,5
2,2
1,5
2,0
3,0
2,4
3,2
4,6
6,4
8,3
11,7
5,5
7,4
10,4
20
20
25
3807
3807
3810
*
*
*
2,5
2,5
2,5
14
14
14
6,0
6,0
6,0
10
10
10
1,0
1,0
1,0
18
18
18
6,0
6,0
6,0
10
10
10
3,3
3,3
3,3
7,3
7,3
7,3
2,25
(20)
2UC32-
2UC33-
2UC33-
2EA1
0FA1
7FA1
E
F
22,0
30,0
37,0
30,0
40,0
50,0
35,1
45,6
57,0
71,0
96,0
114,0
80,0
104,0
130,0
96,0
114,0
135,0
104,0
130,0
154,0
125
200
200
3832
3140
3142
25,0
70,0
70,0
3
2/0
2/0
35,0
150,0
150,0
2
300
300
25,0
50,0
70,0
3
1/0
2/0
35,0
150,0
150,0
2
300
300
20,0
55,0
55,0
44,0
121,0
121,0
50
(445)
MICROMASTER 440
Operating Instructions (Compact)
2UC23
-0CA1
3,0
4,0
6,0
15,6
13,6
25
3810
*
4,0
12
10,0
8
1,5
16
10,0
8
5,5
12,1
2UC34-
5FA1
45,0
60,0
67,5
135,0
154,0
164,0
-
250
3144
95,0
3/0
150,0
300
95,0
3/0
150,0
300
55,0
121,0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Micromaster 440 series

Table of Contents