Download Print this page

Maintenance - Toshiba RAS-07~13 S2A Series RAS-13SKP-E Owner's Manual

Advertisement

Available languages

Available languages

  • ENGLISH, page 1
11
TEMPORARY OPERATION
In case of the misplaced or discharged remote control
• Pressing the RESET button, the unit can start or stop
without using the remote control.
• Operation mode is set on AUTOMATIC
operation, preset temperature is 24°C
and fan operation is automatic speed.
TIMER OPERATION
12
Setting the ON Timer
1
ON
Press
: Set the desired ON
timer.
2
Press
: Set the timer.
SET
3
Press
: Cancel the timer.
CLR
Everyday timer allows the user to set both the ON & OFF timers and will
be activated on a daily basis.
Setting Everyday Timer
1
3
Press
ON
: Set the ON timer.
2
4
OFF
Press
: Set the OFF timer.
• During the every day timer is activating, both arrows ( , ) are indicated.
Note:
• Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur.
• The setting will be saved for the next same operation.
PRESET OPERATION
13
Set your preferred operation for future use. The setting will be memorized by the
unit for future operation (except airfl ow direction).
1. Select your preferred operation.
PRESET
2. Press and hold
for 3 seconds to memorize the setting. The P mark
displays.
PRESET
3. Press
: Operate the preset operation.
AUTO RESTART OPERATION
14
To automatically restart the conditioner after the power failure (Power of the
unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5
seconds)
• Do not operate ON timer and OFF timer.
2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel
the operation. (3 beep sound but OPERATION lamp does not blink)
15
QUIET OPERATION
To operate at super low fan speed for quiet operation (except in DRY mode)
QUIET
Press
: Start and stop the operation.
Note: Under certain conditions, QUIET operation may not provide adequate
cooling due to low sound features.
16
COMFORT SLEEP OPERATION
To save energy while sleeping, automatically control air fl ow and automatically
turn OFF.
COMFORT
SLEEP
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase).
17
SLEEP TIMER OPERATION
To start the sleep timer (OFF timer) operation
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
SLEEP
18

MAINTENANCE

Firstly, turn off the circuit breaker.
Filter Reset (Some models only)
FILTER lamp lights on; the fi lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit or the FILTER
button on the remote control.
Setting the OFF Timer
OFF
Press
: Set the desired OFF
timer.
Press
: Set the timer.
SET
Press
: Cancel the timer.
CLR
SET
Press
.
SET
Press
button during the ( or )
mark fl ashing.
Indoor Unit and Remote Control
• Clean the indoor unit and the remote control with a wet cloth when
needed.
• No benzine, thinner, polishing powder or chemically-treated duster.
SELF CLEANING OPERATION
19
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during "Cool" or "Dry" mode, the fan will
continue to run for other 20 minutes, then it will turn off automatically. This
will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
Note:
• SELF CLEANING operation is default setting from factory.
• To cancel this function, press and hold the reset button on the indoor unit
for 20 seconds.
The SELF CLEANING operation will be cancelled. (5 beep sound but
OPERATION lamp does not blink)
• Do the same to set this function again. (5 beep sound and OPERATION
lamp blink 5 time/sec for 5 seconds)
• AUTO RESTART operation will be cancelled by setting or cancellation of
SELF CLEANING operation. Set it again if necessary.
20
OPERATION AND PERFORMANCE
1. Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2. Some minor cracking sound may occur when unit operating. This is normal
because the cracking sound may be caused by expansion / contraction of
plastic.
Air conditioner operating conditions
Temp.
Outdoor Temperature
Operation
Cooling
21°C ~ 43°C
Dry
19°C ~ 43°C
21
TROUBLESHOOTING (CHECK POINT)
The unit does not operate.
• The power main switch is turned
off.
• The circuit breaker is activated to
cut off the power supply.
• Stoppage of electric current
• ON timer is set.
22
REMOTE CONTROL A-B SELECTION
To separate using of remote control for each indoor unit in case of 2 air conditioners
are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the pencil. "00"
CHK ●
will be shown on the display.
MODE
4. Press
during pushing
. "B" will show on the display and "00"
CHK ●
will disappear and the air conditioner will turn OFF. The Remote Control B is
memorized.
Note: 1. Repeat above step to reset Remote Control
to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.
3 times within 30 seconds.
EN
Room Temperature
21°C ~ 32°C
17°C ~ 32°C
Cooling is abnormally low.
• The fi lters are blocked with dust.
• The temperature has been set
improperly.
• The windows or doors are opened.
• The air inlet or outlet of the outdoor
unit is blocked.
• The fan speed is too low.
• The operation mode is FAN or
DRY.

Advertisement

loading

This manual is also suitable for:

Ras-07skp-eRas-07~13 skp seriesRas-10skp-e