12 Functional Descriptions
12.35 Uninterruptible power supply (UPS) (as from SW 6.3) (Express shutdown)
Example: PLC program for the initiation of an "Express shutdown"
A
DB255
L
KF 10
T
DW 10
L
KH 0201
T
DW 11
L
KH 0319
T
DW 12
L
KH 001
T
DW 13
L
KH 5F02
T
DW 14
L
KH 2F04
T
DW 15
L
KH 0090
T
DW 16
BA
FX73
OEM-SEND
DBTY
KC DB
DBNR
KF
255
DWNR
KF
10
QTTG
KF
192
.
.
.
BA
FX74
OEM-EMPF
DBTY
KC DB
DBNR
KF
255
DWNR
KF
20
OEMN
KF
0
QTTG
KF
195
Data received:
(as acknowledgement, "Express shutdown" implemented, the I code is returned)
DB 255
DW20
KH = 0004
DW21
KH = 0319
DW22
KH = 0201
DW23
KH = 0001
DW24
KH = 0000
DW25
KH = 2F04
DW26
KH = 0094
12–358
User DB
Package length
Sender (PLC)
Receiver (MBX)
Task data structure
Task number
I code
Control flag
Scanning of the OEM information bit (PLC-MD 137).
Only once bit "0" or "1" has been set, then data
(acknowledgement) are present in the mailbox.
In this dependency the FX74 is called up.
Package length
Sender (MBX)
Receiver (PLC)
Task data structure
Task number
I code
Control flag