Nozzle Length; Offset - K-TEK MT5000 Installation & Operation Manua

Guided wave radar level transmitter
Table of Contents

Advertisement

4.3.5. NOZZLE LENGTH

In this selection you will enter the length of the mounting nozzle from the face of the cou-
pler to the top of the tank. Transmitters with a Mounting Type of Plate will have a Nozzle
Length of 0. This entry will tell the transmitter to ignore any reading within the nozzle area.
(Figure 12)
To enter the NOZZLE LENGTH:
1. Press and hold the SELECT button for 2 seconds.
2. Scroll UP or DOWN to set each digit.
3. Press the SELECT button to set the digit and move to the next digit in sequence.
4. After the last digit is set, press the SELECT button to set the new NOZZLE LENGTH.
5. Scroll UP or DOWN to END MENU.
6. Pressing the SELECT button now will return you to the main screen.

4.3.6. OFFSET

Offset is a value in engineering UNITS which may be entered to compensate for an un-
measureable area below a probe or to align the measurement of the MT5000 with another
device. The value entered in the Offset will be Added to or subtracted from the LVL indica-
tion on the main display. (Figure 13)
To enter the LVL OFFSET:
1. Press the SELECT button.
2. Scroll UP or DOWN to set each digit.
3. Press the SELECT button to set the digit and move to the next digit in sequence.
4. After the last digit is set, press the SELECT button to set the new LVL OFFSET.
5. Scroll DOWN to END MENU.
6. Pressing the SELECT button now will return you to the main screen.
MT5000-0200-1 Rev f (10-2010) DCN0528
Nozzle Length
Figure 12
NOZZLE LENGTH
XX.XX in
mA
LVL: XX.XX in
XX.XX
OFFSET
XX.XX in
mA
LVL: XX.XX in
XX.XX
14