MicroLogix™ 1200 Isolated Relay Output Module
Wire Size and Terminal Screw Torque
Each terminal accepts up to two wires with the following restrictions:
Wire Type
Solid
Cu-90°C (194°F)
Stranded
Cu-90°C (194°F)

I/O Memory Mapping

Addressing
The addressing scheme for 1762-OX6I is shown below.
Output Data File (0)
Output (O) File
(1)
I/O located on the controller (embedded I/O) is slot 0. I/O added to the controller (expansion I/O) begins with slot 1.
Output Data File
Relay outputs are controlled using the bit positions in Word 0, as follows:
• 1 = relay energized (normally-open contact ON)
• 0 = relay not energized (normally-closed contact ON)
For each module, the output data file contains the controller-directed state of the
discrete output points. Bit positions 0 through 5 correspond to output points 0
through 5.
15
14
13
0
0
0
0
w = write only; 0 = always at 0 or OFF state
Publication 1762-IN017B-EN-P - March 2004
Wire Size
#14 to #22 AWG
#16 to #22 AWG
Slot Number
O0:x.0/0
Slot Delimiter
Word Delimiter
12
11
10
9
0
0
0
0
(1)
Word
Bit Delimiter
Bit Position
8
7
6
5
0
0
0
w
Terminal Screw Torque
0.904 Nm (8 in-lbs)
0.904 Nm (8 in-lbs)
Bit
4
3
2
w
w
w
1
0
w
w