Precautions

On Using and Storing the Camera

This section explains how to safely use, store and
clean the camera.
When setting up the camera
• Do not attach the zoom lens without reading
"Attaching the Zoom Lens and Optional Filter" on
page 25. Attaching the lens incorrectly may damage
the lens.
• Do not directly connect the camera to an AC power
line. Use the recommended camera adaptor or use a
12 volt DC power source.
• Do not block air circulation about the camera to
prevent internal heat build-up.
When operating the camera
• Avoid rough handling or mechanical shock.
• Avoid strong magnetic fields to prevent signal
distortion.
• Avoid operating the camera in environments that
exceed the temperature range of –5˚C to +45˚C (23˚F
to 113˚F).
• Do not grip the camera by the viewfinder.
When using a supplied viewfinder
Do not leave the viewfinder so that sunlight can enter
the eyepiece lens. It is possible for sunlight focused
by the eyepiece to cause very high temperatures, and
melt the inside of the viewfinder
When storing and shipping the camera
• Cover the lens with the supplied lens cap when you
do not plan to use the video camera for an extended
period of time.
• When you transport the camera, repack it as it was
originally shipped. Do not discard the packing
carton. This affords maximum protection whenever
you ship the camera. Do not ship or transport the
camera in the carrying case alone.
• Store the camera with the viewfinder moved fully in
the direction opposite the viewfinder barrel and the
lock ring tightened. (See page 28.)
When cleaning the camera
• Clean the cabinet, panel and controls with a soft, dry
cloth or a cloth moistened with a mild detergent
solution.
• Do not use any type of solvent, such as alcohol or
benzine which might damage the finish.
If you have any questions about this camera, contact
your authorized Sony dealer.
6
Managing Hyper-Sensitivity in the
CCD Image Sensor
Because of the high sensitivity of the CCD image
sensors, the following phenomena may appear on the
monitor screen while you are using the DXC-327B-
series color camera. These phenomena do not mean
that there is anything wrong with the camera.
Vertical smear
Smear tends to happen when an extremely bright object
such as an electric light, fluorescent lamp, sunlight, or
strong reflection is being shot.
Video
monitor
screen
White dots
White dots may appear in the video output if the
camera is used at very high temperatures.
Aliasing
Aliasing may occur when you shoot fine stripes or
straight lines. The lines appear jagged.
Poor pictures
You may not get a clear picture if the GAIN selector is
set to 18 dB when you are using the electronic shutter.
Use the electronics shutter under lighting conditions
where you can obtain a clear picture with the GAIN
selector set to the 0 or 9 dB position.
Light belt-like line
(smear phenomenon)
A very bright object is
shot. (Such as electric
light, fluorescent lamp,
sunlight, strong
reflected light)