GENERAL SERVICE HINTS FOR METER
CONTROL
Problem
Softener delivers hard water
Cause
Reserve capacity has been exceeded.
Meter is not measuring flow.
Correction
Check salt dosage requirements and reset reserve
capacity to provide additional reserve.
On Mechanical Meter: Check with meter checker kit.
If volume is not registering, check the meter cap and
impeller for debris, and ensure they can move freely.
On Electronic Meter: Check for a short in the meter
cable. Ensure that it is programmed as a meter, and
that the turbine and impeller can move freely.
FLECK
7000XTR Service Manual