Troubleshooting - Pentair FLECK 7000XTR Service Manual

Water softener control valve
Table of Contents

Advertisement

TROUBLESHOOTING

Timer
If an error is detected, an error screen will alternate with the
main display screen every few seconds, and the LED light will
be red.
During an error condition, the unit continues to monitor
the flow meter and update the remaining capacity. Once an
error condition is corrected, the unit returns to the operating
status it was in prior to the error, and regeneration resumes
according to normal programming. If an error is cleared by
reprogramming the unit in the Master Programming Mode,
the volume remaining may be reset to the full unit capacity
(as though it had just regenerated). If an error is present,
a regeneration can only occur manually by pressing and
holding the Extra Cycle button for 5 seconds. If the unit was
in regeneration when the error occurred, it will complete the
regeneration cycle and go into service.
When the problem is corrected, and the error no longer displays
(it may take several seconds for the unit to stop displaying the
error message), the unit will return to normal operation. The
LED light will no longer be red, and will turn Green if the unit is
regenerating, or Blue if the unit is in service.
Problem
Flashing/blinking
Power outage has occurred. Either wait 5
display
minutes for blinking to stop, or press any
key on the keypad.
Unit not responding
Verify the unit is configured correctly (ex:
after going into
wiring valve type). Perform a Master Reset
regeneration
by holding the Shift button and cycling
power. Check and verify the choices
selected in Master Programming Mode.
Unit displays "ERROR
Contact your local water treatment
CODE: REPLACE UNIT"
professional.
(corrupted UAP)
Error
Display
Code
Message
01
ERROR CODE:
PROGRAM UNIT
02
ERROR CODE:
PROGRAM UNIT
03
ERROR CODE:
SERVICE UNIT
Programming Mode. Manually initiate a
regeneration cycle by pressing the Extra
04
ERROR CODE:
SERVICE UNIT
Programming Mode. Manually initiate a
regeneration cycle by pressing the Extra
05
ERROR CODE:
SERVICE UNIT
professional as soon as possible. Leave
NOTE: If the above corrections do not work, please contact
your local water treatment professional.
Correction
Correction
Go through all screens in Master
Programming Mode.
Go through all screens in Master
Programming Mode.
Perform a Master Reset by holding
the Shift button and cycling power.
Go through all screens in Master
Cycle button for 5 seconds.
Perform a Master Reset by holding
the Shift button and cycling power.
Go through all screens in Master
Cycle button for 5 seconds.
Call your local water treatment
the unit running (do not unplug).
Error Display Screen Examples:
FLECK
7000XTR Service Manual
• 17