Table 15:
Key
8.1.4

Display

On the front of the enclosure there is a backlit LCD.
6 x 12 pixel characters
Graphical LCD 128 x 64 pixels
In figure
module. Row 1 contains mains frequency information. Row 2-3 contains stator information and
row 4-5 rotor information. Column 1 (empty) gives status, column 2 and 3 are informative and
column 4 contains variables, settable by the keypad.
670 series
Operation manual
HMI keys on the front of the injection unit REX060
61
the content of the display is shown for a REX060 with one SIM and one RIM
Function
The Injection switch enables injection at rotor and stator 2 s
after switching on. A LED indicates that the injection switch is
set to enable injection. The injection switch can be padlocked in
off position in order to cut-off both injection signals.
The Key-lock button enables/disables the keypad.
Hold the Key-lock button for a period of 1.2 s to 4 s to lock or
unlock the keys. A key-lock LED indicates when the keypad is
unlocked.
Moves the cursor in the direction of the arrows
When the cursor is in the value change state, pressing the
up button increases the value and pressing the down
button decreases the value.
Pressing the clear button cancels changes that have not been
stored.
Pressing the enter button stores the changed value. If the value
is outside range, the limit value is stored.
Section 8
REX060 injection unit LHMI
GUID-FE74D8A4-BF75-498F-A204-CCB638EC18D1 v1