Sony Betacam SX DNW-A65 Operation Manual page 25

Digital video cassette player
Hide thumbs Also See for Betacam SX DNW-A65:
Table of Contents

Advertisement

6 External device connectors
1 CONTROL PANEL connector
CONTROL PANEL
REMOTE1-IN(9P)
1 CONTROL PANEL connector (29-pin)
After disconnecting the control panel from this unit,
use this connector to connect the 29-way remote
control cable supplied with the control panel extension
kit.
2 REMOTE1-IN(9P) connector (D-sub 9-pin)
When using this unit together with a DNW-A75/A75P
or a D-1, D-2, or Betacam VTR, and a BVE-series
BVE-900/910/2000/9000/9000P/9100/9100P or other
editor, connect a 9-pin remote control cable from the
other unit to this connector. The IN(9P) and OUT(9P)
connectors provide a loop-through connection for
remote control signals.
3 REMOTE1-OUT(9P) connector (D-sub 9-pin)
This provides the loop-through output for remote
control signals from the REMOTE1-IN(9P) connector
2.
7 Power supply section
2 BREAKER button
AC IN
BREAKER
3 Ground terminal
2 REMOTE1-IN(9P) connector
REMOTE1-OUT(9P)
RS-232C
3 REMOTE1-OUT(9P) connector
1 AC IN connector
REMOTE 2
PARALLEL I/O(50P)
VIDEO CONTROL
5 VIDEO CONTROL connector
4 RS-232C connector
4 RS-232C connector (D-sub 9-pin)
Use this for monitoring and diagnosis of the state of
this unit from an external computer, using ISR
(Interactive Status Reporting).
5 VIDEO CONTROL connector (D-sub 15-pin)
For remote control of the internal digital video
processor, connect an optional BVR-50/50P Remote
Control Unit or similar.
Always power off this unit before connecting the
remote control unit.
6 REMOTE 2 PARALLEL I/O (50P) connector
(D-sub 50-pin)
Connect remote control signals from an external
device.
For details, refer to the Installation Manual.
1 AC IN connector
Use the optional power cord to connect this to an AC
outlet.
2 BREAKER button
This jumps out if an excess current flows on the
primary side of the AC power circuit.
3 Ground terminal
Connect this to ground.
Chapter 2 Location and Function of Parts
6 REMOTE 2 PARALLEL I/O (50P)
connector
2-17