Connect Status - Rentokil Connect AutoGate Instruction Manual

Table of Contents

Advertisement

Connect Status

The messages that are sent to the server are:
Technician Test Pass: When the AutoGate passes through the technician test and displays
the ON indicator.
Technician test Fail: If any of the tests fail when the AutoGate is tested
Technician Visit: If the AutoGate is visited and the button is pressed in any of the first 3
selections but the Technician test is not carried out.
AutoGate Closed: This is the initial state of the AutoGate and indicates that this gate has
not been opened since it was last visited.
AutoGate Open: If a particular gate sees the programmed number of activations then the
gate will open and report this status
AutoGate Remotely Opened: If another AutoGate in the same zone has detected activity
then the server will send a command to the gate to remotely open and this status will be
reported.
AutoGate Re-Closed: After the programmed open time (default 5 days) the gate will close
and report this status.
AutoGate Re-Opened: If another activation is detected then the gate will open
immediately and report this status. Note: other gates in the zone are not opened in this
case.
iR Sensors Blocked: If there is an issue with the internal sensors then this error status will
be sent back.
Other data that is sent back from the AutoGates is: Battery Voltage, Signal Strength,
number of activations since reset and active count (i.e. not timed out).
Page 13
Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)