Page 1
Connect AutoGate Instruction Manual Relates to : Connect AutoGate – 304765 This product has LongReach Technology Inside This manual is based on the latest information and is provided subject to alteration. Instruction Manual PestConnect / 2017 Version 0.4 GSD-100548...
Page 2
When you’ve no more use for it, please dispose of the product according to your local authority’s recycling scheme. For more information, please contact your local authority or the retailer where you bought the product. Page 2 Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Safety Instructions This product is intended for indoor or outdoor use. • Only use the battery packs part number 300076 supplied by Rentokil • Initial for this product. NOTE: This battery pack is not rechargeable and should never be recharged.
Page 4
Panels to ensure high levels of connectivity. NOTE: The control panels that are suitable for using with AutoGate Connect must also be equipped with LongReach technology. Radar Connect AutoGate Connect Figure 1: Connect System Overview Page 4 Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
The AutoGate Connect units will fit into FT150 and FT155 bait boxes (shown below). Page 5 Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Gate Armed – means that the AutoGate has been set up correctly. Note: If this LED is lit together with any of the first 3 then the gate will continue to function after the display goes out. Indicating that there have been 4 activations Page 7 Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Page 8
With the “External LED” on the AutoGate on the right hand side, insert the AutoGate into place such that the door is in the middle of the bait box and the support arms are either side of the walls as shown below. Page 8 Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Page 9
E.g. “r8” as shown. If there is no connection only the “r” will be displayed while scanning. Once the Gate is tested and connected to the Control Panel the ON symbol is lit as shown. Page 9 Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
In signal strength test mode, a value between “r0” and “r9” will be displayed. AutoGates should not be deployed when the signal strength shows “r0” and installing another Control Panel would be advised. Page 10 Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Remove the old battery and recycle. Push the button to ensure that any remaining charge on the board is discharged before plugging the new battery into the board. Page 11 Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
1 to 30 is the number of days that it will stay open. 5. Press the button to scroll through and choose the required setting 6. Release the button and wait 5 seconds for the setting to be stored. Page 12 Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Sensors Blocked: If there is an issue with the internal sensors then this error status will be sent back. Other data that is sent back from the AutoGates is: Battery Voltage, Signal Strength, number of activations since reset and active count (i.e. not timed out). Page 13 Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
(to discharge the capacitor) and replug the battery. If this persists another cause could be that there are more than 300 devices connected to the control panel already. Page 14 Instruction Manual Connect AutoGate/ 2017 Version 0.4 (GSD-100548)
Operating Temperature IP21 Environmental rating M ounts in the Rentokil FT150 & FT155 bait boxes M ounting The Autogate is intended for outdoor use but should not be located where more than 3cm of standing water is likely to occur.