Maintenance

MAINTENANCE
Risk of electric shock. Can burn or cause
death. Disconnect the power before servicing, repairing,
or working on pump.
The pump's motor is completely sealed in the motor
housing and does not require any service. Disassembly
of the motor housing or modification or removal of
the power cord voids the warranty. The power cord is
non-replaceable.
Never run the pump dry! Running the pump dry can
damage the seal, causing leakage. This pump is a sub-
mersible type and must be in water at all times for prop-
er operation and cooling.
Periodically clean the pump inlet. This will avoid impel-
ler rotation being hampered by any debris.

Troubleshooting

NOTICE: This pump has no serviceable parts inside the
motor housing. Opening the motor housing will ruin the
pump. If obstructions or blockages of the impeller cannot
be cleaned out as described above, or by backflushing
into the discharge with a garden hose, replace the pump.
SYMPTOM
POSSIBLE CAUSE(S)
Pump won't
Blown fuse or circuit breaker has tripped
start or run
Low line voltage
Defective motor
Pump operates but
Low line voltage
delivers little or no
water
Something caught in impeller
Worn or defective parts
Check valve installed without
vent hole
Intermittent running
Thermal overload has tripped
or pump stopped
automatically
For parts or assistance, call Simer Customer Service at 1-800-468-7867
To Clean Inlet/Impeller
1. Unplug pump.
2. Remove baseplate by turning in direction of
OPEN arrow. Clean out inlet.
3. Remove screw holding volute base to pump housing.
4. Turn volute base in direction of OPEN arrow and
remove. Clean out impeller.
To reinstall, reverse above directions. Be sure to replace
O-Ring and engage volute base tabs with pump housing
before replacing screw.
Hazardous voltage; can shock, burn or kill.
Unplug the pump before attempting to clean or work on
the pump.
CORRECTIVE ACTION
If blown, replace with fuse of proper size or reset circuit breaker
If voltage under recommended minimum, check size of wiring from main
switch on property. If OK, contact power company or hydro authority
Replace pump
If voltage under recommended minimum, check size of wiring from main
switch on property. If OK, contact power company or hydro authority.
Cleanout or replace pump
Replace pump
Drill a 1/16" - 1/8" (1.6mm - 3.2mm) dia. hole between pump discharge
& check valve. Drilled hole must be located below the waterline.
Protect the installation from the sun
Pump cooler water
Pump has run dry; add water