Item
Standard
Cooling
N/A
Vibration Operating
1
IEC60068-2-6
Shock Operating
1
IEC60068-2-27
Ambient Operating
N/A
Temperature
2
Storage Temperature
N/A
Humidity
N/A
Altitude
UL 60950-1
UL 60950-1
Environment
1
Applies only to 19" Displays with solid state hard drive.
2
For ambient temperatures greater than 50°C (122 °F), the unit must be installed in a restricted access area as defined in this
document.
Overview
For public disclosure

1.1.3 Environmental Specifications

Caution
Note For additional product standards and agency approvals, refer to
Description
Natural convection
(Sine): 10 - 57 Hz, 0.152 mm (0.006 in) displacement peak-peak
57 - 500 Hz, 1.0 g acceleration
(Half-sine) 15 g pk, 11 ms
0 to 60°C (32 to 140 °F) (SSD)
0 to 40°C (32 to 104 °F) (HDD)
-20 to 60°C (-4 to 140 °F)
10 to 85% non-condensing
0 to 2,000 m (0 to 6,562 ft)
Pollution Degree 2
This applies where there is only non-conductive pollution that might temporarily
become conductive due to occasional condensation.
Warning
Caution
The RXi Display should be installed in a location
that is not exposed to corrosive gases or liquids,
rain, or direct sunlight, and that meets the
environmental specifications listed in the following
table.
If the RXi Display is operating in ambient
temperatures greater than 50°C (122 °F), its exterior
temperatures may be too hot to touch safely. To
avoid burn hazards, the unit must be installed in a
restricted access area, as defined by:
• • Access can only be gained by service persons or by
users who have been instructed about the reasons
for the restrictions applied to the location and about
any precautions that shall be taken; and
• • Access is through the use of a tool or lock and key,
or other means of security, and is controlled by the
authority responsible for the location.
EMC Requirements:
When installing, operating, or maintaining the RXi
Box IPC, personnel must ensure that any
electrostatic charge is discharged using a grounded
Electrostatic Discharge (ESD) strap or other means.