9

MAINTENANCE

Incorrect maintenance/repair!
Danger to life and equipment damage.
1. Check and clean the delivery and suction fi lters daily or as necessary.
2. Carry out every shut down as explained in paragraph 7.2.
3. As necessary, check and replace hoses, pipes, and connections daily.
In accordance with the guideline for liquid emitters (ZH 1/406 and BGR  500 Part  2
Chapter 2.3):
- The liquid emitters should be checked by an expert (e.g. Wagner service technician)
for their safe working conditions as required and at least every 12 months.
- For shut down devices, the examination can be suspended until the next start-up.
ORDER NUMBER DOC 2330426
WARNING
Only a WAGNER service center or a suitably trained person may
carry out repairs and replace parts.
Only repair and replace parts that are listed in the chapter "Spare
Parts Catalogue" and that are assigned to the unit.
Before all work on the unit and in the event of work interruptions:
- Disconnect the control unit from the mains.
- Relieve the pressure from the spray gun and unit.
- Secure the spray gun against actuation.
Observe the operating and service instructions when carrying
out all work.