FC1: Operation for Legally Relevant Functionalities
Note: For devices used in legal metrology, official documents may exist
prescribing how the security switch has to be sealed. Please refer to the
Appendix, if applicable.

5.2 LEDs

There are two multicolor LEDs on the front panel, the Power LED and the

Status LED.

5.2.1

Power LED

LED status
Off
Red
Green
Orange
5.2.2
Status LED
This paragraph describes the behavior of the status LED for devices used in
legal metrology (e.g. according to MID/EU-type examination certificate).
The status LED indicates whether an error affecting the legally relevant
functionalities, i.e. an alarm or a warning, is pending or has been pending.
An alarm is an error event affecting the legally relevant functionalities
severely; the calculation of the fiscal results is stopped.
In case of a warning, a minor error has occurred but the calculation of the
fiscal results is continued.
enCore FC1
Meaning
Power off; no USB connection
Power off, USB connection detected
Power on, no USB connection
Power on, USB connection active
Table 8: Power LED