Honeywell enCore FC1 Instructions For Use Manual page 13

Flow computer
Hide thumbs Also See for enCore FC1:
Table of Contents

Advertisement

FC1: General Information
European Standards
The FC1 flow computer supports the following European calculation
standards:
Value to be calculated
Compressibility factors at
measurement and base
conditions (Zm, Zb)
Density,
relative density
Heating values,
Wobbe indices
Parameterization
The FC1 flow computer is configured by using the parameterization software
that is included in the enSuite software collection and runs on a PC or laptop
(Windows).
2
When selecting the calculation standard, the regulations of the EU type-examination
certificate must be observed.
enCore FC1
Selectable calculation standards
AGA8-92 DC (ISO 12213-2)
SGERG-88 (ISO 12213-3)
2
AGA-NX19 mod
AGA-NX19 mod BR.KOR.3H
AGA-NX19 GOST
GOST 30319-2
GOST 30319-3
ISO 6976 (for Zb)
Zm/Zb = constant
Zm via compressibility factor table
AGA8-92 DC
ISO 6976
ISO 6976
Table 5: Supported calculation standards
Use in Legal Metrology
4
Page 13 of 61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents