FC1: Technical Data

7.3 Outputs

MFA8 output board

7.4 Interfaces for Digital Communication

CPU
MSER4
ESER4
MFE7
USB port
Ethernet
communication
Serial communication
Table 17: Communication interfaces: Technical specifications
enCore FC1
1 PhotoMos output (NC, max. 28.8 V, 120 mA)
for alarm/message signaling
3 PhotoMos outputs (NO, max. 28.8 V DC,
120 mA) for alarm/message or pulse outputs of
up to 25 Hz
4 analog outputs 0/4 ... 20 mA for measurements
Table 16: Outputs: Technical specifications
LAN interface (Ethernet 10/100MBit)
2 serial ports (supported standards:
RS485/RS422/RS232),
the first port can be used as DSfG protocol
interface
4 serial ports, electrically isolated (supported
standards: RS485/RS422/RS232)
3 serial ports, electrically isolated (supported
standards: RS485/RS422/RS232)
LAN interface (Ethernet 10/100MBit)
1 serial RS485 interface
USB interface for PC or laptop connection for
parameterization and service purposes
NTP, Modbus TCP, FTP, HTTP
Modbus (ASCII, RTU), UNIFORM
Use in Legal Metrology