Gas Quality Afb - Honeywell enCore FC1 Instructions For Use Manual

Flow computer
Hide thumbs Also See for enCore FC1:
Table of Contents

Advertisement

5
Qc
10
Table 11: Hyperlinks in Flow Conversion's main display
5.4.2

Gas Quality AFB

For most applications, the calculation of the conversion factor is performed
by the
G a s Q u a l i t y A F B
indicated in the main display of the responsible
shown in Table 10, this display can be activated by using the
factor hyperlink in the
Alternatively, the main display of the
using the corresponding button in the home display as usual.
The labels of some of the measurements that are shown in the Gas Quality's
main display are designed as hyperlinks, too.
Figure 10 shows a typical example of a Gas Quality main display; Table 12
lists the target displays of the hyperlinks as well as the values and
measurements included.
10
Qc is replaced by Qm if no gas meter correction is parameterized.
Page 36 of 61
FC1: Operation for Legally Relevant Functionalities
Flow rates
. The measurements used for this calculation are
F l o w C o n v e r s i o n A F B
Use in Legal Metrology
QE
Energy flow rate
QM
Mass flow rate
Qb
Base volume flow rate
Qc
Corrected volume flow
rate
Qm
Flow rate for volume at
measurement conditions
Cf
Correction factor
G a s Q u a l i t y A F B
(fiscal display).