Figure 5.6-6: Aib Rs-422 Interface Schematic; Table 5.6-3: Aib-485 Pin Designations - Moog 903 User Manual

Fiber optic video/data multiplexer fmb-x-2.5 version
Hide thumbs Also See for 903:
Table of Contents

Advertisement

903-0623-00 Rev. A
Full duplex communication runs transmit and receive on separate conductors, thus autosense is not
required. The AIB modules support full duplex transmission as either RS-422 or TTL data.
Connector pin designations for the front panel WAGO connectors are given in the table below with default
configuration shaded.
Pin
RS-485 Designation
1
2
3
4
Switch settings for the various configurations are given in Table 5.6-4. When using the module in RS-422
or TTL input configuration, the autosense mode (SW3, SW4) should be set for full-duplex operation.
Autosense baud rate settings (SW5) are ignored when the module is in full-duplex or simplex modes.
Focal Technologies Corp.

Figure 5.6-6: AIB RS-422 Interface Schematic

Table 5.6-3: AIB-485 Pin Designations

RS-422 Designation
TX+/RX+
TX-/RX-
N/C
N/C
Model 903 User's Guide, FMB-X-2.5 Version
TTL Designation
RX+
TTL IN
RX-
N/C
TX+
TTL OUT
TX-
ISOGND
Page 5-27