Safety Precautions; Notes On Usage - Kikusui TOS93 series User Manual

High voltage scanner
Hide thumbs Also See for TOS93 series:
Table of Contents

Advertisement

Safety Precautions

When using this product, be sure to observe the precautions in
the Safety Information manual. Items specific to this product
are given below.
• You will receive a potentially fatal electric shock if:
• You touch an output terminal while output is being gener-
ated.
• You touch a test lead that is connected to an output termi-
nal while output is being generated.
• You touch the EUT while output is being generated.
• You touch a location that is electrically connected to an
output terminal while output is being generated.
• You touch a location that is electrically connected to an
output terminal immediately after output is turned off after
a DC withstanding voltage test or insulation resistance
test has been performed.
• You may receive a potentially fatal electric shock if:
• You operate the tester without grounding it.
• You operate the tester without using rubber gloves for
electrical work.
• You come close to a location that is electrically connected
to an output terminal while output is being generated.
• You come close a location that is electrically connected to
an output terminal immediately after output is turned off
after a DC withstanding voltage test or insulation resis-
tance test has been performed.
• Do not touch the tip of the test lead with your hand.
Risk of electric shock.
• Do not use this product near highly sensitive measur-
ing instruments or receivers.
Noise generated by this product may affect other devices.
At a test voltage of 3 kV or greater, the product may pro-
duce corona discharge between its test lead clips. This will
generate a significant amount of broadband RF emission.
To minimize this effect, keep the alligator clips away from
each other. Also, keep the alligator clips and test leads
away from conducting surfaces, especially sharp metal
edges.
• Do not exceed the stacking limit.
Stack only a single TOS9320 scanner on top of a TOS93
series tester. Otherwise, it may cause injury to the operator
or damage to the product when it falls down.
If you are using multiple TOS9320 scanners, rack mount
them, or install them next to the tester. When stacking scan-
ners, do not stack more than two scanners.
TOS9320

Notes on Usage

• When installing this product, be sure to observe the tem-
perature and humidity ranges indicated below.
Operating temperature range: 0 °C to 40 °C (32 °F to
104 °F)
Operating humidity range: 20 %rh to 80 %rh (no condensa-
tion)
• When storing this product, be sure to observe the tempera-
ture and humidity ranges indicated below.
Storage temperature range: -20 °C to 70 °C (-4 °F to
158 °F)
Storage humidity range: 90 %rh or less (no condensation)
5
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tos9320

Table of Contents