Rules For Installation - LA NORDICA ELLIPSE Use And Maintenance

Table of Contents

Advertisement

Available languages

Available languages

ELLIPSE
Singular feature of the model "Carillon" is the pivoting body, i.e. the possibility of rotating the stove of +-
45° (with regard to its base axis) also when is lighted. It is also possible to block the appliance at the
wished position by a knob. (Picture 1 pos.A)
The one-piece ceramic glass of the door (resistant up to 700 °C) allows a wonderful view on the burning
flames. Furthermore, it is thus avoided the output of sparks and smoke.
Below the hearth grate there is an extractable ash drawer, (Picture 9 pos. A).
The heating of the environment is made by irradiation: through the panoramic glass and the external hot
surfaces of the stove, the heat is radiated into the environment.
The stove is equipped with controls of primary and secondary air by which it is adjusted the combustion air.
1 - PRIMARY air register (left lever)
Below the hearth door, on the front left side, there is the primary air
register, in the style of lever (Picture 1 - 1)
With this air register, it is adjusted the passage of primary
air into the low part of the stove and through particular
A
channels flows in the fuel direction. The primary air is
necessary for the combustion process during lighting. The
ash drawer must be regularly emptied, so that the ash
does not obstruct the entry of the primary air for the
combustion.
In order to open the air flow, the bar must be completely
pulled out,
1
During wood combustion, the register of primary air must
be opened only for a while, because otherwise the wood
burns too fast and the stove may overheat. For the coal
combustion, the arrival of primary air is absolutely
necessary (see paragraph 10).
A
2 - SECONDARY air register (right lever)
2
Below the hearth door, on the right front side there is the
secondary air register (Picture 1 - 2).
Picture 1
The secondary air, passing through the two lateral jambs
of the front side, heats itself starting the double combustion and keeping at the same time the glass clean
(with open register).
When the bar is pushed to the back the passage of the secondary is completely open (Picture 1 - 2).
3.

RULES FOR INSTALLATION

The stove, assembled and ready for the installation, must be connected with a junction to the existing flue
of the house. The junction must be possibly short, straight, horizontal or positioned a little uphill. The
connections must be tight.
It is obligatory to respect the National and European rules, local regulations concerning building
matter and also fireproof rules. Please apply to your chimney sweeper for all information.
You should verify the sufficient air entrance for the combustion in the installation place, with particular
attention to windows and doors with tight closing (seal ropes).
It is not allowed the connection of various appliances to the same chimney. The diameter of the opening for
the connection must correspond at least to the diameter of the smokes pipe. The opening should be
equipped with a wall connection for the reception of the exhaust pipe and a rose window.
Before installation, verify if your floor can support the weight of the stove (for ex. distributing weight plate).
Please do not install the stove in a inclined level in order to avoid tensions during the rotation.
LA NORDICA is not responsible in case of modification of the product and for the use of not
original spare parts. The hearths must not be modified. THE HEARTHS MUST NOT BE MODIFIED.
18
7196901 Rev.09 – EN