Introduction; Specifications; Electrical: Input/Output - Walchem WCU Series Instruction Manual

Electroless copper controller
Table of Contents

Advertisement

1.0

Introduction

The WCU310 series copper controllers are optoelectronic on-line analyzers that may
be used in variety of applications including electroless copper baths, microetch baths
and a number of other chemistries that contain more than 0.10 grams/liter (g/L) of
copper ions.
There are four relays that may be used as control outputs that are activated
simultaneously. The direction of control is selected via software. The outputs each
have timers associated with them, that may be used to track the volume of chemistry
added, or the time that the output has been on.
An optional 4-20 mA output that is proportional to the copper concentration is
available.
Either an immersible in-tank sensor or flow-through out-of-tank sensor may be
specified.
2.0

Specifications

2.1
Measurement Performance
Electroless Copper Concentration Range:
Microetch Copper Concentration Range:
Concentration Resolution:
Concentration Accuracy:
2.2

Electrical: Input/Output

Input Power
110-120 VAC
50/60 Hz, 10A
Input Signals
Sensor
Interlock (optional)
Output
Mechanical Relays (5)
4 - 20 mA (optional)
or
220-240 VAC
50/60 Hz, 5A
Power: + 5VDC, 150 mA
Signals: 0 to 2VDC
Isolated dry contact closure required (i.e., flow,
level, etc.)
@ 120 VAC, 10A resistive, 1/8 HP
@ 240 VAC, 5A resistive, 1/8 HP
internally powered, switching line voltage
Fully isolated, internally powered 600 Ω max.
resistive load. Resolution .001% of span, accuracy
± 1% of reading.
1
.01 - 5.5 g/L (.001 - 0.73 oz/gal)
.01 - 99 g/L
(.001 – 13.2 oz/gal)
.001 g/L
(.0001 oz/gal)
.01 g/L
(.001 oz/gal)