RS-232C command table

<How to read the command table>
Command :
Direction :
Parameter :
Reply :
A circle indicates commands which can be used in power standby mode.
Power control, etc.
CONTROL ITEM
POWER SETTING
CHANNEL DISPLAY
VOLUME
MUTE
SYNC CHECK
CAUSE OF LAST STANDBY
CAUSE OF LAST ERROR
POWER CONTROL
LANGUAGE
RESET
46
US
Command field
38
W
When the "Parameter" is set in the parameter field (
command functions as described under "Control/Response Contents".
R
The returned value indicated under "Reply" can be obtained by setting
"????", "___?" or "???+" (repeater control) in the parameter field (
38
Parameter
Response
Command
Direction
POWR
W
R
DISP
W
VOLM
WR
MUTE
WR
SYNC
W
STCA
W
R
ERCA
WR
BRIGHTNESS
VLMP
WR
POWER
PMNG
WR
LANG
WR
RSET
W
RSE+
W
Returned value
Parameter
Reply
0
Switches to standby.
1
Returns from standby.
0
Standby state
1
Normal status
2
Power standby state ("Mode2" in "Power Management").
It displays channel display.
0 - 60
0 - 60
0
0
OFF
1
1
ON
0
It returns Yes/No.
1
It returns frequency.
0
Content initialization
No standby operation (except remote control and monitor button operation) after
0
initialization
1
Electrical standby due to some error condition (See cause of last error)
2
Invalid input has continued for a long time during PC display
3
It entered standby mode (PC mode: "Mode1" in "Power Management")
4
It entered standby mode (PC mode: "Mode2" in "Power Management")
6
It entered standby mode by the command from RS-232C.
0
Content initialization
0
No detectable error has occurred
1
Invalid input has continued for a long time during PC display
2
Internal bus error
3
Abnormal temperature
4
Board connection error
5
Lamp error
7
Electrical system error
8
Error in communication with microcomputer
±8
±8
Brightness
0
0
Off
1
1
Mode1
2
2
Mode2
1
German
2
French
4
Spanish
13
Japanese
14
English
4 digits
Input 4-digit PIN for parameter. It resets to factory preset value.
Input 4-digit PIN for parameter. It resets to factory preset value. For Repeater
4 digits
control
38